American Standard 3572, 3574, 3575 manual Leveling Stringer Not, For Support, 914mm

Models: 3572 3575 3574

1 16
Download 16 pages 28.94 Kb
Page 5
Image 5
LEVELING STRINGER NOT

ROUGHING-IN REFERENCES

GREEN TEA™ 5-1/2' x 36"

 

MODEL 3572 AIR BATH

 

TOP VIEW

 

66

 

(1676mm)

14-3/4

 

 

 

(292mm)

OUTLINE OF CUTOUT 64.5 x 34.5 (1638 x 876mm)

11-1/2

(292mm)

 

 

 

 

 

 

36

 

 

 

(914mm)

BLOWER

 

 

 

 

 

9

C

 

 

(229mm)

L

CUTOUT IN FLOOR FOR DRAIN

 

PROVIDE ACCESS TO BLOWER FOR

CONTROL

22 AIR JETS

SERVICE ON ALL INSTALLATIONS

 

PANEL

 

END VIEW

C

LEVELING STRINGER NOT

 

51mm

L TO OVERFLOW

102mm (4")

FOR SUPPORT

 

(2")

 

 

 

559mm

 

 

INTEGRAL FEET

(22")

 

 

WITH ATTACHED

508mm

 

BASEBOARD

 

(20")

 

ROUGH

 

 

 

FLOOR

 

1-1/2" N.P.T.M. THREADS

35mm

98mm

 

1-1/2" O.D. TAILPIECE

 

(1-3/8")

(3-7/8")

GREEN TEA™ 5' x 42"

MODEL 3574 AIR BATH

TOP VIEW

END VIEW

GREEN TEA™ 6' x 36"

MODEL 3573 AIR BATH

72

(1829mm)

 

 

14-3/4

 

 

(375mm)

OUTLINE OF CUTOUT 70.5 x 34.5 (1780 x 876mm)

11-1/2

 

 

(292mm)

 

 

36

BLOWER

 

(914mm)

 

 

 

9

C

 

(229mm)

L

 

 

 

CUTOUT IN FLOOR

 

FOR DRAIN

 

PROVIDE ACCESS TO BLOWER FOR

CONTROL

23 AIR JETS

SERVICE ON ALL INSTALLATIONS

PANEL

 

 

C

LEVELING STRINGER NOT

51mm

L TO OVERFLOW

102mm (4")

FOR SUPPORT

 

(2")

 

 

 

559mm

 

 

INTEGRAL FEET

(22")

 

 

WITH ATTACHED

508mm

 

BASEBOARD

 

(20")

 

ROUGH

 

 

 

FLOOR

 

1-1/2" N.P.T.M. THREADS

35mm

98mm

 

1-1/2" O.D. TAILPIECE

 

(1-3/8")

(3-7/8")

GREEN TEA™ 6' x 42"

MODEL 3575 AIR BATH

60

(1524mm)14-3/4 (375mm)

TOP VIEW

OUTLINE OF CUTOUT 58.5 x 40.5 (1486 x 1029mm)

 

11-1/2

 

 

 

(292mm)

BLOWER

9

(229mm)

CUTOUT IN FLOOR FOR DRAIN FOR SUPPORT

42

(1067mm)

C

L

TOP VIEW

72

(1829mm)14-3/4(375mm)

OUTLINE OF CUTOUT 70.5 x 40.5 (1780 x 1029mm)

 

11-1/2

 

 

(292mm)

42 (1067mm)

(914mm)BLOWER

9

C

(229mm)

L

CUTOUT IN FLOOR FOR DRAINManual background

PROVIDE ACCESS TO BLOWER FOR

CONTROL

 

PROVIDE ACCESS TO BLOWER FOR

CONTROL

27 AIR JETS

23 AIR JETS

SERVICE ON ALL INSTALLATIONS

PANEL

 

SERVICE ON ALL INSTALLATIONS

PANEL

 

 

 

 

 

 

END VIEW

 

 

 

END VIEW

 

 

 

 

 

 

 

 

C

LEVELING STRINGER NOT

 

C

 

 

51mm

L TO OVERFLOW

 

LEVELING STRINGER NOT

102mm (4")

FOR SUPPORT

51mm

L TO OVERFLOW

(2")

 

102mm (4")

FOR SUPPORT

 

 

 

(2")

 

 

 

 

 

 

 

 

 

 

 

559mm

 

 

INTEGRAL FEET

559mm

 

 

INTEGRAL FEET

(22")

 

 

WITH ATTACHED

(22")

 

 

WITH ATTACHED

508mm

 

BASEBOARD

508mm

 

BASEBOARD

 

(20")

 

ROUGH

 

(20")

 

ROUGH

 

 

 

FLOOR

 

 

 

FLOOR

 

 

 

 

 

1-1/2" N.P.T.M. THREADS

 

 

 

1-1/2" N.P.T.M. THREADS

35mm

98mm

 

35mm

98mm

 

1-1/2" O.D. TAILPIECE

 

1-1/2" O.D. TAILPIECE

 

(1-3/8")

(3-7/8")

 

(1-3/8")

(3-7/8")

 

 

 

 

754063-100 Rev. B