American Standard 4114.1 Check Connections For Leaks, Service, Hot Limit Safety Stop Adjustment

Models: 4114.1

1 4
Download 4 pages 53.35 Kb
Page 4
Image 4
5 CHECK CONNECTIONS FOR LEAKS.

5 CHECK CONNECTIONS FOR LEAKS.

Move HANDLE down into "off" position.

Turn on water supplies and check connections for leaks. 6 SERVICE

Operate HANDLE (2) up and down, left and right to flush water lines thoroughly.

Operate HAND SPRAY and check connections for leaks. Clogged CARTRIDGE outlets or inlets may cause reduced flow.

CHECK CONNECTIONS

FOR LEAKS HOT LIMIT SAFETY STOP ADJUSTMENT

6 SERVICE

If faucet drips, operate HANDLE several times from "off" to "on." Do not apply excessive force.

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).

 

 

 

Pull off ESCUTCHEON CAP (4). Unscrew three MOUNTING SCREWS (5).

 

 

 

Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8).

2

 

3

Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).

 

 

 

Place SEALS (8) into CARTRIDGE PORTS (6A).

1

 

4

Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING

 

 

 

SCREWS (5) alternately.

 

 

 

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE

 

 

5

SCREW (1) and install INDEX BUTTON (2).

 

 

HOT LIMIT SAFETY STOP ADJUSTMENT

 

 

6

By restricting handle rotation and limiting the amount of hot water allowed

 

 

 

6A

 

to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental

 

8

scalding. To set the maximum hot water temperature of your faucets, all you

 

 

 

 

 

need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

 

7

 

Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (5). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE SCREW (1) and install INDEX BUTTON (2).

"A"

PRY RED RING FORWARD AND ROTATE COUNTER- CLOCKWISE ONE CLICK

TEMPERATURE

SETTING NUMBERS

"B"

 

PRY RED RING FORWARD

 

AND ROTATE CLOCKWISE

"B"

"B"

 

ADJUSTMENT WHEN

 

WATER IS TOO COLD

 

 

 

 

 

 

"A"

 

 

 

 

 

"A"

 

 

 

 

0

ADJUSTMENT WHEN

 

 

 

1

 

 

4

 

2

 

 

WATER IS TOO HOT

3

 

 

 

5

 

 

 

 

 

6

 

 

 

 

6

 

 

 

 

 

5

"RED RING"- HOT LIMIT SAFETY STOP

7 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968470 REV. 1. 4

Page 4
Image 4
American Standard 4114.1 Check Connections For Leaks, Service, Clogged CARTRIDGE outlets or inlets may cause reduced flow