American Standard 4114.100 EverClean Finish Care Instructions,  Check Connections For Leaks

Models: 4114.100

1 3
Download 3 pages 20.15 Kb
Page 3
Image 3
 CHECK CONNECTIONS FOR LEAKS.

 CHECK CONNECTIONS FOR LEAKS.

Move HANDLE down into "off" position.

Turn on water supplies and check connections for leaks.  SERVICE

Operate HANDLE (2) up and down, left and right to flush water lines thoroughly.

Operate HAND SPRAY and check connections for leaks. HOT LIMIT SAFETY STOP ADJUSTMENT

CHECK CONNECTIONS

FOR LEAKS 23

 SERVICE

If faucet drips, operate HANDLE several times from "off" to "on." Do not apply excessive force.

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3). Pull off ESCUTCHEON CAP (4). Unscrew three MOUNTING SCREWS (5).

Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8). Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).

Place SEALS (8) into CARTRIDGE PORTS (6A).

Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING SCREWS (5) alternately.

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE SCREW (1) and install INDEX BUTTON (2).

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (5). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten

"A"

PRY RED RING FORWARD

HANDLE SCREW (1) and install INDEX BUTTON (2).

AND ROTATE COUNTER-

 

CLOCKWISE ONE CLICK

23

1 EverClean™ Finish Care Instructions 4

5

6

6AManual backgroundManual backgroundManual background 8

7 Manual background

5&.1&3"563&

4&55*/(/6.#&34

"B"

 

PRY RED RING FORWARD

 

AND ROTATE CLOCKWISE

"B"

"B"

 

ADJUSTMENT WHEN

 

WATER IS TOO COLD

 

              









 



 



 



 



 







 

"A"

"A"

ADJUSTMENT WHEN Manual background WATER IS TOO HOT

6

5

3&%3*/()05

-*.*54"'&5:4501

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.