American Standard 4147.100 Test Installed Faucet, Service, EverClean Finish Care Instructions

Models: 4147.100

1 3
Download 3 pages 25.25 Kb
Page 3
Image 3
TEST INSTALLED FAUCET

TEST INSTALLED FAUCET

Move HANDLE (1) into "off" position and remove AERATOR (2).

3

Turn on water supplies and check connections for leaks.

 

2

Operate HANDLE (1) on and off, hot and cold to flush water lines

1

thoroughly.

 

Pull SPRAY (3) out and activate. Check hose and supply connections for leaks.

Move HANDLE (1) to "off" position and replace SPRAY (3) and AERATOR (2).

CHECK FOR LEAKS

SERVICE

Reduced flow. If the flow should gradually be reduced over a number of months, the AERATOR may have debris in it. To clean, remove AERATOR (7) and rinse with water to remove any debris. Turn on faucet to wash any debris out of the faucet. Screw AERATOR (7) back into the spout. Operate faucet.

Clogged CARTRIDGE outlets or inlets may cause reduced flow. To clean, first turn off water supply then:

Remove BUTTON (1) and loosen HANDLE

 

SCREW (1) with 2mm Hex Wrench then pull off

7

HANDLE (2).

 

Unscrew ESCUTCHEON CAP (3). Unscrew the

CARTRIDGE NUT (4).

Remove CARTRIDGE (5). Clean inlets of CARTRIDGE (5) and MANIFOLD (6).

Reassemble CARTRIDGE (5). Replace CARTRIDGE NUT (4), CAP (3) and HANDLE (6) assembly, check flow.

1

3

4

5

2

6

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.