FPS1000 Instruction Manual

CHAPTER 3 FPS1000 POWER SUPPLY INSTALLATION

3.1 GENERAL

This chapter contains instructions for initial inspection, preparation for use and repackaging forshipment.

NOTE

FPS1000 power supplies series generate magnetic field which might affect the operation of other instruments. If your equipment is susceptible to magnetic fields, do not position it adjacent to the FPS1000 unit.

3.2 PREPARATION FOR USE

In order to be operational the power supply must be connected to an appropriate AC source.

The AC source voltage should be within the power supply specification. Do not apply power before reading sections 3.6 and 3.7.

Table 3-1 below describes the basic setup procedure. Follow the instructions in Table 3-1 in the sequence given to prepare the power supply for use.

Step no

Item

Description

Reference

1

Inspection

Initial physical inspection of the power supply

Section 3.3

2

Installation

Installing the power supply.

Section 3.4

 

 

Ensuring adequate ventilation.

Section 3.5

3

AC source

AC source requirements

Section 3.6

4

Load connection

Wire size selection. Local / Remote

Section 3.7

 

 

sensing. Single or multiple loads.

 

Table 3-1: Basic setup procedure

 

 

3.3 INITIAL INSPECTION

Prior to shipment this power supply was inspected and found free of mechanical or electrical defects. Upon unpacking of the power supply, inspect for any damage which may have occurred in transit. The inspection should confirm that there is no exterior damage to the power supply.

Keep all packing material until the inspection has been completed. If damage is detected , file a claim with carrier immediately and notify the Lambda sales or service facility nearest you.

3.4 FPS1000 MOUNTING

The FPS1000 power supplies series is designed to fit in the FPS-S1U and FPS-T1U, 19" rack, or in an equivalent rack designed for the FPS1000 power supply.

The FPS1000 is secured to the rack using the spring lock device, located at the FPS1000 front panel. Refer to the FPS1000 and the FPS-S1U and FPS-T1U outline drawings in Chapter 2, Chapter 11 and Chapter 18.

When installation using mounting screws is required, the FPS1000 can be secured to the equipment using the M3 mounting holes at its bottom surface. Refer to the FPS1000 outline drawings.

3.5 LOCATION MOUNTING AND COOLING

This power supply is fan cooled. The air intake is at the front panel and the exhaust is at the rear panel. Upon installation allow cooling air to reach the front panel ventilation inlets and allow minimum 50mm of unrestricted air space at the rear of the unit for the air exhaust.

3.6 AC SOURCE REQUIREMENTS

The FPS1000 series can be operated from a nominal 100V to 240V, single phase, 47~63Hz. Refer to the specifications in chapter 1 for the input voltage range and the current required.

Ensure that under heavy load, the AC voltage supplied to the power supply does not fall below the "low limit" specifications.

CAUTION

WARNING

Connection of this power supply to an AC power source should be made by an electrician or other qualified personnel.

There is a potential shock hazard if the power supply chassis and cover are not connected to an electrical safety ground via the safetyground in the AC input connector.

7

Page 10
Image 10
TDK FPS1000-32, FPS-T1U, FPS1000-12, FPS-S1U, FPS1000-48, FPS1000-24 manual FPS1000 Power Supply Installation

FPS1000-32, FPS-S1U, FPS1000-48, FPS1000-12, FPS-T1U specifications

TDK has established itself as a leading innovator in power supply solutions with its range of FPS series products, specifically designed for various demanding applications. Among these, the FPS1000-24, FPS-T1U, FPS1000-12, FPS1000-48, and FPS-S1U models stand out due to their advanced features, robust technologies, and versatile characteristics.

The FPS1000-24, catering to a voltage output of 24V, is ideal for both industrial and commercial applications. It delivers a notable output power of 1000 watts while boasting high efficiency, making it a reliable option for systems that require consistent power with minimal energy loss. The model incorporates advanced protection features including over-voltage, over-current, and short-circuit protection, ensuring that connected devices are safeguarded against potential electrical faults.

Similarly, the FPS1000-12 offers a 12V output with equivalent power ratings, making it suitable for applications such as telecommunications and medical devices where stability and reliability are paramount. This model also emphasizes thermal management, utilizing integrated cooling technologies to maintain optimal performance even under demanding conditions.

The FPS1000-48 distinguishes itself with a 48V output, which is increasingly prevalent in high-density computing environments and server applications. With enhanced scalability, this model allows for multiple unit configurations to support higher load demands while maintaining exceptional efficiency levels.

In addition to the standard offerings, TDK’s FPS-T1U and FPS-S1U models provide intelligent power management solutions. The FPS-T1U, being a compact version, is tailored for space-constrained environments, ensuring high performance without compromising on size. It features built-in monitoring capabilities that allow users to track power usage and efficiency metrics in real-time.

The FPS-S1U is particularly notable for its modular design, enabling easy integration into various systems. This flexibility allows users to adapt the power supply to specific system requirements, enhancing functionality across diverse applications. Both models leverage cutting-edge technology to ensure low standby power consumption, reducing the overall energy footprint.

Overall, TDK’s FPS series exemplifies a commitment to quality, performance, and adaptability, making them ideal candidates for modern power supply needs across industries. With their comprehensive protection mechanisms, efficiency, and innovative designs, they stand as reliable choices for engineers and designers looking to optimize their systems.