29
Fig 10-2: FPS1000 modules location
10.7.6 Modules location
Up to three FPS1000 modules of the same output voltage rating can be plugged into an FPS-S1U rack.
Refer to Fig 10-2 for the modules location.
10.7.7 Blank panels
Each FPS-S1U rack is supplied with two blank panels in the package. Use the blank panels to close the
front panel opening in places where FPS1000 power supplies are not installed. Use M3x6 screws to fix
the blank panel to the chassis. Refer to the outline drawings in chapter 11 for details.
10.7.8 Repackaging for shipment
Refer to Sec. 3.7.8 for details.
Air flow direction
Front side
see note 1
PS MODULE “A”
PS MODULE “B”
PS MODULE “C”
Note 1: Forced air cooling allow minimum 50mm of unrestricted air space at the rear of the unit. Do not
obsruct air flow to the unit front panel.
FPS-S1U Instruction Manual