10 TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate
Release
if necessary.
ON
1
OFF
COLD
HOT
4
3
5
WASTE
OUTLET
2
2 | “P” TRAP |
|
11 SERVICE
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Loosen SET SCREW (2) with 2.5mm hex wrench. Pull HANDLE (1) off valve stem. Pull off
CAP (3). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT
SAFETY STOP (4). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" | |
being the hottest to "7" the coldest temperature setting. Factory set at "0". | 1 |
|
Replace ESCUTCHEON CAP (3), HANDLE (1), tighten HANDLE SCREW (2).
PRY RED RING FORWARD
| "A" AND ROTATE COUNTER- |
| ||
|
| CLOCKWISE ONE CLICK |
| |
|
|
| "A" |
|
TEMPERATURE |
| 0 |
| |
SETTING NUMBERS |
| 1 | "A" | |
| 2 | |||
"B" |
| 4 | 3 | |
| 5 |
| ADJUSTMENT WHEN | |
PRY RED RING FORWARD |
| 6 |
| |
| 7 |
| WATER IS TOO HOT | |
AND ROTATE CLOCKWISE | "B" |
|
|
|
"B" |
|
|
| |
|
|
|
| |
ADJUSTMENT WHEN |
|
|
| 4 |
WATER IS TOO COLD |
|
|
|
"RED RING"- HOT LIMIT SAFETY STOP
2
3
12 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
4