6 SERVICE
AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR. Clean AERATOR and FLOW RESTRICTOR. Replace AERATOR.
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE. Clean inlets and MANIFOLD.
HANDLE
SET SCREW
HANDLE
BUSHING
CAP
HOT LIMIT
STOP
CARTRIDGE
SCREWS
CAP
RETAINER
CARTRIDGE
SEALS
ROD
Reassemble CARTRIDGE, alternately tightening screws. Replace HOT LIMIT STOP , CAP and HANDLE. Check flow.
7 8 5 1 7 Rev. 1 . 1
HOT LINE FOR HELP
For
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO
P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . © A S A m e r i c a , I n c . 2 0 0 8