American Standard M968852 Service, Test Installed Faucet, Care Instructions

Models: M968852

1 4
Download 4 pages 34.97 Kb
Page 3
Image 3
5 SERVICE

5 SERVICE

To change direction of handle rotation, proceed as follows:

6 TEST INSTALLED FAUCET Turn valve to OFF position.

7 CARE INSTRUCTIONS: Thread counter-clock wise HANDLE BASE (1) to remove HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).

Manual background Use a flat blade screw driver to remove SPRING CLIP (4).

Manual background Lift STOP WASHER (5), turn 90˚ and replace.

Manual background Replace SPRING CLIP (4). Manual background Reinstall HANDLE ASSEMBLY (2).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

4

1

TO REMOVE HANDLE

90˚

3

5

2

6 TEST INSTALLED FAUCET

Turn HANDLES to "off" position.

Remove AERATOR (1) using TOOL (2) supplied.

Turn hot and cold water supplies on. Operate both HANDLES to flush water lines thoroughly. Check spout connections for leaks.

Check all drain connections for leaks.Manual background

Turn handles to OFF position. Replace AERATOR (1).

1

2 Manual background

7 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968852 Rev.1.3

Page 3
Image 3
American Standard M968852 installation instructions Service, Test Installed Faucet, Care Instructions