1 TRIM INSTALLATION

Remove PLASTER GUARD (1) if attached.

Push CAPS (2 & 2a) as shown onto CONTROL VALVES (3).

2

4

Push ESCUTCHEON HOLDER (4) with lightly greased O-RING SEALS (5) over CAPS (2, 2a).

Attach the FIXATION PLATE (7) to the ESCUTCHEON HOLDER (4) with the two SCREWS (6) provided.

Push ESCUTCHEON (8) flush against finished wall.

3

1

2a6

5

7

8

12 INSTALL HANDLES

Attach HANDLE ADAPTER (1) to KNOB MOUNT (2) with SCREW (3). Align HANDLE (4) as shown and push onto KNOB MOUNT (2). Tighten SET SCREW (5) with HEX WRENCH (6) supplied with trim kit. Install HANDLE SCREW (7) into VALVE STEM (8) and tighten.

Align HANDLE (9) as shown and push onto HANDLE SCREW (7). Tighten SET SCREW (5a) with HEX WRENCH (6) su pplied with trim kit.

8

7

9

5a

2

1 4

3 5

6

3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION

Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:

Shut off water supply.

Remove handle and rim. (Reverse steps 1 and 2).

Remove check stops and re-install them transposed.

Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.

Turn the water supply back on and perform the temperature adjustment in step 4.

Assemble HANDLES and TRIM.

CHECK STOP

(BLUE TO RED)

CHECK STOP

(RED TO BLUE)

M 9 6 8 0 2 2

Page 2
Image 2