Upgrading Firmware
89
MVP-5100/5150 Modero Viewpoint Touch Panels
7. Select Tools > Firmware Transfers > Send to NetLinx Device from the main menu to open the
Send to NetLinx Device dialog (B in FIG. 73). Verify that the panel’s System and Device number
values match those values listed within the System folder in the OnLine Tree tab of the Workspace
window (A in FIG. 73).
8. Select the panel’s Kit file from the Files section.
9. Enter the Device value associated with the panel and the System number associated with the Master
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.
10. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update
process is complete.
11. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the
dialog (B in FIG. 73).
12. After the file transfer is complete, the panel will automatically reboot. As the panel is rebooting,
temporarily unplug the USB connector on the panel until the panel has completely restarted.
13. Once the first panel page has been displayed, reconnect the USB connector to the panel.
14. Right-click the associated System number and select Refresh System. This causes a refresh of all
project systems, establishes a new connection to the Master, and populates the System list with
devices on your particular system.
15. Confirm that the panel has been properly updated to the correct firmware version.
FIG. 73 Using USB for a Virtual Master transfer
AB
Verify you have downloaded the latest firmware file from www.amx.com and then
save the Kit file to your computer.