AMX RDC-DC specifications Setting AXlink and PROlink Address Numbers, Lighting Application Drawing

Models: RDC-DC

1 2
Download 2 pages 20.5 Kb
Page 2
Image 2
Dry Closure Default Presets

Dry Closure Default Presets

Contact Closure Default Function

1Channel 1 at 100% in 1 second

2Channel 2 at 100% in 1 second

3Channel 3 at 100% in 1 second

4Channel 4 at 100% in 1 second

5Channel 5 at 100% in 1 second

6Channel 6 at 100% in 1 second

7Pack on (channels 1-6)

8Pack off (channels 1-6

All other channels are undefined.

Setting AXlink and PROlink Address Numbers:

AXlink Address

PROlink Address

Test

Set the AXlink address number (1-255) for the RDC-DC. This number must match the device number in your Axcess program.

Use the PROlink DIP switch to set the PROlink address number for the RDC-DC (1-10).

Pin 8 on the PROlink DIP switch is a test switch that turns all circuits on to full.

FIG. 6 Setting AXlink and PROlink address numbers.

Lighting Application Drawing

F1

RDC-DC/120

Panel

All neutrals are common to the Neutral block in the enclosure. Provide a separate neutral for each load.

AMX Corporation reserves the right to alter specifications without notice at any time.

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

043-019-2242 8/01 ©2001 AMX Corporation. All rights reserved.

The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without notice at any time.

3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993