AMX RDC-PDC Connecting Dry Closures, Setting AXlink and PROlink Address Numbers, Method a

Models: RDC-PDC

1 4
Download 4 pages 5.45 Kb
Page 2
Image 2

Connecting Dry Closures

Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.

Dry Closure Default Presets (Cont.)

5

Channel 5 at 100% in 1 second

1 2 3 4 5 6 7 8 COM

FIG. 5 Dry closures connection

Each contact (1 - 8) is pre- programmed with a default preset.

Refer to the AMX Lighting Control

System instruction manual for details on dry closure default presets and recording new presets.

6

Channel 6 at 100% in 1 second

 

 

7

Pack on (channels 1-6)

 

 

8

Pack off (channels 1-6

All other channels are undefined.

Setting AXlink and PROlink Address Numbers:

AXlink Address

PROlink Address

 

 

 

Test

 

 

 

Each contact closure connection (1 - 8) is pre-programmed with a default preset. The table below shows the default presets for each contact clo- sure.

Dry Closure Default Presets

Contact Closure Default Function

1Channel 1 at 100% in 1 second

2Channel 2 at 100% in 1 second

3Channel 3 at 100% in 1 second

4Channel 4 at 100% in 1 second

Set the AXlink address number

Use the PROlink DIP switch to set

(1-255) for the RDC-DC. This

the PROlink address number for the

number must match the device

RDC-DC (1-10).

number in your Axcess program.

Pin 8 on the PROlink DIP switch is

 

 

a test switch that turns all circuits on

 

to full.

FIG. 6 Setting AXlink and PROlink address numbers.

Lighting Application Drawings

Method A

RDC-PDC/120, 3 Phase 6 dimmers, 0 switches

FIG. 7 Method A

2

RDC-PDC Control Card, Dual or Three Phase

Page 2