Emerson P/N 400361-00 SPIO Name, SPIO.#.Name, SPIO State, SPIO.#.Out, SP Menu Decimal, SP Menu ID

Models: P/N 400361-00

1 152
Download 152 pages 17.97 Kb
Page 121
Image 121
SPIO Name

SPIO Name

SPIO.#.Name

Each digital I/O point on the Unidrive SP can be given a name. The name can be used in a user program to reference a specific I/O point. The name can be up to 12 alphanumeric characters, but must begin with a non-numeric character.

SPIO State

SPIO.#.Out

The first three digital I/O points on the Unidrive SP (pins 24, 25, and 26) are configured as Inputs or Outputs using PowerTools Pro EZ software. If the I/O points have been configured as digital outputs, then the SPIO.#.Out signal can be used in a user program to activate an output, or on the Assignments view to activate when a specified Source event activates. If assigned to a source on the assignments view, when the source event activates, the output that it is assigned to will turn on.

Note

This parameter will appear on the Assignments view under the Outputs group of Destinations even if the I/O point has been configured as a digital input.

SP Menu Decimal

SPMenu.Decimal

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

SP Menu Drive Decimal

SPMenu.DriveDecimal

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

SP Menu Error Status

SPMenu.ErrorStatus

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter

using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

SP Menu ID

SPMenu.MenuID

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

SP Menu Parameter ID

SPMenu.ParamID

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

SP Menu Value

SPMenu.Value

This parameter is used behind the scenes in PowerTools Pro EZ when reading or writing to a SP menu parameter using the Drive Watch Window icon. These are not to be used inside a user program.

If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction, MM represents the desired menu, and PP represents the desired parameter number.

Unidrive SP Power Up Time – Hrs.Min

SPPowerUpTimeHoursMinutes

The Drive Power Up Time is the time elapsed since power has been cycled to the Unidrive SP. The format for this parameter is Years.Days and Hours.Minutes. These values must be used in combination to find the actual time. This parameter can be found on the Errors view while Online with PowerTools Pro EZ.

Total Power Up Time = SPPowerUpTimeYearsDays + SPPowerUpTimeHoursMinutes

Parameter Descriptions

www.emersonct.com

107

Page 121
Image 121
Emerson P/N 400361-00 SPIO Name, SPIO.#.Name, SPIO State, SPIO.#.Out, SP Menu Decimal, SPMenu.Decimal, SPMenu.DriveDecimal