add a level of protection from exceeding the machines travel limits. The SoftwareTravelLimitMinusActive source (output function) is active when the SoftwareTravelLimitMinusPosn is reached or exceeded. Motion is halted using the TravelLimitDecel whenever a hardware or software travel limit is hit or exceeded. Software travel limits are not active unless Absolute Position Valid is active.
Software Travel Limit Minus Active
SoftwareTravelLimitMinusActive
The SoftwareTravelLimitMinusActive source is active when the SoftwareTravelLimitMinusPosn is reached or exceeded. Motion will come to a stop using the TravelLimitDecel ramp. Software travel limits are not active unless enabled and Absolute Position Valid is active.
Software Travel Limit Minus Position
SoftwareTravelLimitMinusPosn
The SoftwareTravelLimitMinusActive source will activate when the SoftwareTravelLimitMinusPosn is reached or exceeded. Motion will come to a stop using the TravelLimitDecel. Software travel limits are not active unless enabled and Absolute Position Valid is active.
Software Travel Limit Plus Active
SoftwareTravelLimitPlusActive
The SoftwareTravelLimitPlusActive source is active when the SoftwareTravelLimitPlusPosn is reached or exceeded. Motion will come to a stop using the TravelLimitDecel ramp. Software travel limits are not active unless enabled and Absolute Position Valid is active.
Software Travel Limit Plus Position
SoftwareTravelLimitPlusPosn
The SoftwareTravelLimitPlusActive source is active when the SoftwareTravelLimitPlusPosn is reached or exceeded. Motion is halted using the TravelLimitDecel whenever a hardware or software travel limit is hit or exceeded. Software travel limits are not active unless enabled and Absolute Position Valid is active.
Unidrive SP I/O Status Word
SPConnect.DigitalIOReadWord
This parameter is a bitmap that contains the status of the digital I/O on the Unidrive SP. This parameter is
Unidrive SP Encoder Supply Voltage
SPDrive.EncoderSupplyVoltage
The Unidrive SP is capable of supporting multiple voltage
levels for external encoders. This parameter defines the supply voltage put out to the external encoder and can be found on the Hardware > Drive / Encoder view in PowerTools Pro EZ. For all of the standard motors offered in the Motor Type list box, the Encoder Supply Voltage should be set to 5V (default). This parameter is
Unidrive SP Encoder Revolution Counter
SPDriveEncRevCount
This
Unidrive SP Fine Encoder Position
SPDriveEncRevFinePosition
This
(232) of a revolution since those are the units used by the Unidrive SP and its’ option modules. The value for this parameter comes from parameter 3.30 of the Unidrive SP database.
Early releases of the
Unidrive SP Encoder Position
SPDriveEncRevPosition
This
(216) of a revolution since those are the units used by the Unidrive SP and its’ option modules. The value for this parameter comes from parameter 3.29 of the Unidrive SP database.
Unidrive SP Drive Status Bitmap
SPDriveStatus
The SPDriveStatus parameter is a decimal value that equates to the state of the Status Bits in the Unidrive SP. This is a
Bit 15 = Not Used | Not Used |
Bit 14 = Parameter 10.15Mains Loss
Parameter Descriptions | www.emersonct.com | 105 |