13.5Clearing the SM-EZMotion module memory

The SM-EZMotion module has a function that allows the user to clear the module memory. Doing so will erase the configuration stored in the module. To procedure for erasing the module configuration is as follows:

1.Navigate to parameter 18.01 on the keypad

2.Press the Mode button mode

3.Enter the value 19237

4.Press the Mode button view mode

Mto enter parameter edit

Magain to return to parameter

Figure 119: Status Online Tab

Many of the views in PowerTools Pro have Online tab that contain parameters related to that View when online with the drive.

13.4Clearing SLX.dF trip after installing SM-EZMotion module

After installing a SM-EZMotion module for the first time, the Unidrive SP will display a SLX.dF trip (where X is the slot number that the SM-EZMotion module is in). This trip occurs because the drive detects the module type in the slot has changed. This trip will occur on each successive power up until the drive parameter database has been saved. To save the drive parameter database, follow the instructions below.

Saving the Drive Parameters

When changing a parameter in Menu 0, the new value is

saved automatically when pressing the Mode button M

to return to parameter view mode from parameter edit mode.

If parameters have been changed in the advanced menus, then the change will not be saved automatically. A save function must be carried out.

The procedure for saving the parameters is as follows:

1.Enter the value 1000 in MM.00, where MM is any menu number.

2. Press the red Reset button.

St /R t

5.Remove AC power from the Unidrive SP

6.Restore power to the Unidrive SP

After performing the clear memory sequence, the SM-EZMotion module will cause a SLX.Er trip (where X indicates the slot number that the SM-EZMotion module is fitted in). The Error Code for the SM-EZMotion module will be “107 – No Program Error” indicating that the module has no configuration stored in it. Download a new configuration using PowerTools Pro EZ to clear the trip.