Emerson P/N 400361-00 manual SM-EZMotion Module Setup Parameters, x.01 - Option ID Code

Models: P/N 400361-00

1 152
Download 152 pages 17.97 Kb
Page 128
Image 128
12.3SM-EZMotion Module Setup Parameters

Notes:

1.The SM-EZMotion module reads this parameter for display purposes in PowerTools Pro Software. Primary use is for diagnostics.

2.These parameters are set to a specific value every time the system is powered up. This parameter must not be changed, or the system may not function properly.

3.This parameter is read from and written to based on the value specified in PowerTools Pro. This parameter is often directly displayed on a specific view, and can be modified using PowerTools Pro. Written to by the module on every power up.

4.This is the main command signal from the SM-EZMotion module. This parameter is written to every trajectory update of the SM-EZMotion module. Do not attempt to write to this parameter.

5.These parameters are not available in PowerTools Pro, but are written to by the SM-EZMotion module. These parameters are written on every power up. Do not change these parameters.

6.These parameters are reserved for use by the SM-EZMotion module only if an SM-I/O Plus module is being used. If multiple SM-I/O Plus modules are used, these parameters affect the functionality of the SM-I/O Plus module in the lower slot number.

7.These parameters are reserved for use by the SM-EZMotion module only if a second SM-I/O Plus module is being used. These parameters affect the functionality of the SM-I/O Plus module in the higher slot number.

12.3SM-EZMotion Module Setup Parameters

Several parameters associated with the SM-EZMotion option module can be found in either Menu 15, 16, or 17. Each of menus 15, 16, and 17 refer to one of the available slots into which the SM-EZMotion option module can be fitted.

The following SM-EZMotion parameters are available from the keypad on the Unidrive SP. The slot # that the module is plugged into directly determines which menu these parameters are found under.

Slot 1 – Menu 15

Slot 2 – Menu 16

Slot 3 – Menu 17

x.01 – Option ID Code

When no option module is fitted in the relevant slot, this parameter is zero. When a module is fitted in the relevant slot, this parameter displays the identification code of the

module as shown below.

Code

Module

Category

Intelligent

Module

 

 

 

 

 

 

 

0

No Module Fitted

 

 

 

 

 

 

101

SM-Resolver

Position Feedback

 

 

 

 

 

102

SM-Universal

Position Feedback

X

Encoder Plus

 

 

 

 

 

 

 

103

SM-SLM

Position Feedback

X

 

 

 

 

104

SM-Encoder Plus

Position Feedback

 

 

 

 

 

201

SM-I/O Plus

I/O Expansion

 

 

 

 

 

301

SM-Applications

Applications

X

 

 

 

 

302

SM-Applicaitons Lite

Applications

X

 

 

 

 

303

SM-EZMotion

Applications

X

 

 

 

 

401

reserved

Fieldbus

X

 

 

 

 

402

reserved

Fieldbus

X

 

 

 

 

403

SM-Profibus DP

Fieldbus

X

 

 

 

 

404

SM-INTERBUS

Fieldbus

X

 

 

 

 

405

reserved

Fieldbus

X

 

 

 

 

406

SM-CAN

Fieldbus

X

 

 

 

 

407

SM-DeviceNet

Fieldbus

X

 

 

 

 

408

SM-CANopen

Fieldbus

X

 

 

 

 

When the drive parameter database is saved by the user, the option code of the currently fitted module is saved in EEPROM. If the drive is subsequently powered-up with a different module fitted, or no module fitted where a module was previously fitted, the drive will have a SLX.dF trip. To clear the SLX.dF trip, follow the “Clearing the SLX.dF Trip” instructions in the diagnostics section of this manual.

x.02 – Option Software Version

This parameter indicates the SM-EZMotion module firmware revision that is currently stored in the module. It is possible for the user to flash upgrade the firmware using PowerTools Pro EZ software.

The format for this parameter is XX.YY where XX is the major revision and YY is the minor revision. The firmware is released by Control Techniques using an alphanumeric revision code. The first fully released revision is A1.

Anything with a major revision of 50 or greater is considered non-released firmware. When Beta firmware is made available for testing, it is given a beta firmware revision starting at 60.01. The beta firmware revision will increment for each new beta release that is made available (e.g. 60.02, 60.03, etc.).

114

www.emersonct.com

SM-EZMotion Module User Guide

Page 128
Image 128
Emerson P/N 400361-00 manual SM-EZMotion Module Setup Parameters, x.01 - Option ID Code, x.02 - Option Software Version