5.0 ENVIRONMENT:

115V/230V(FULL LOAD):1mS minimum

5.0 ENVIRONMENT:

0°C to +65°C

5.1

AMBIENT OPERATION TEMPERATURE

5.2

AMBIENT OPERATION RELATIVE HUMIDITY

20% to 85%

5.3

AMBIENT STORAGE TEMPERATURE

-40°C to +70°C

AC-V

AC-ON

AC-OFF

PS-ON VB= 4.75V

+5V Wave Form

HIGH

LOW

T2

P.G. WAVE FORM

Manual background T1 Manual background

TURN-ON

T3

ON-RING

OFF-RING

 

POWER GOOD

FIGURE 1

HIGH

T4

POWER FAIL

T5 HOLD-UP

5.4 AMBIENT STORAGE RELATIVE HUMIDITY 10% to 95%

6.0CE REQUIREMENTS:

6.1EMI

Meets FCC PART15 CLASS B

6.2SAFETY REQUIREMENTS Meets UL 1950, Third Edition

Meets EN 60950:1992 +A1:1993 +A2:1993 +A3:1995 +A4:1997 +A11:1997

Meets IEC 60950:1991 +A1:1992 +A2:1993 +A3:1995 +A4:1996

7.0 MTBF at 25°C =80,000 hours

8.0DC CONNECTOR AND CASE REQUIREMENTS

8.1BASEBOARD CONNECTOR

ATX MAIN CONNECTOR (P1)

HOUSING: P/N P20-I42002 OR EQU

4.1 REMOTE ON/OFF CONTROL

The power supply is turn on/off by TTL signal.

Active Low

Power Supply turn on

 

 

Active High

Power Supply turn off

 

 

Remote On/Off Signal Characteristics

PS-ON

MIN

MAX

 

 

 

Vil input low voltage

 

0.8V

Lil, input low current ,Vin=0.4V

 

-1.6mA

 

 

 

Vih, input High voltage, lin=-200uA

2.0V

 

 

 

 

Vih open circuit, lin=0

 

5.25V

 

 

 

4.2 AUXILIARY +5Vsb

This power supply is specifically equipped with an independent stand-by +5V output current, 2.0A max. This output will always provide +5V except when the AC line is cut-off.

4.3 AUTO RESTART

If the power supply's output dropped out of the regulation, which is caused by AC line Voltage, the power supply will automatically resumed normal operation only after the AC line voltage returns to the specified operating range.

TERMINAL: P/N I42002BS-2 OR EQU

16AWG (Wire)

Signal

Pin

Pin

Signal

16AWG (Wire)

Orange

+3.3Vdc

13

1

+3.3Vdc

Orange

Blue

-12Vdc

14

2

+3.3Vdc

Orange

 

 

 

 

 

 

Black

COM

15

3

COM

Black

 

 

 

 

 

 

Green (22AWG)

PS-ON

16

4

+5Vdc

Red

 

 

 

 

 

 

Black

COM

17

5

COM

Black

Black

COM

18

6

+5Vdc

Red

Black

COM

19

7

COM

Black

 

 

 

 

 

 

Empty

Empty

20

8

POK

Gray (22AWG)

 

 

 

 

 

 

Red

+5Vdc

21

9

+5VSB

Purple

 

 

 

 

 

 

Red

+5Vdc

22

10

+12V1dc

Yellow

 

 

 

 

 

 

Red

+5Vdc

23

11

+12V1dc

Yellow

 

 

 

 

 

 

Black

COM

24

12

+3.3Vdc

Orange

 

 

 

 

 

 

5

6