19" LCD Color Monitor

 

AOC 919Swa

5.3Electrical Characteristics

1.TFT LCD Module:

M190MWW3

Note:

A. If it exceeds MIN/MAX values, then "CCFL Life", "ON/OFF Cycle", and "SAFETY" will not be guaranteed. B. CCFL Frequency should be carefully determined to avoid interference between inverter and TFT LCD.

C. The voltage over specified value (VCCFLi) should be applied to the lamp more than 1 second after startup. Otherwise, the lamp may not be turned on. The used lamp current is the lamp typical current. The inverter should be able to give out a power that has a generating capacity of over 1560 voltage. Lamp units need to over 1560 voltage for ignition.

TPM190A1

2.Back Light Unit:

M190MWW3

11

Page 11
Image 11
AOC 919SWA manual Electrical Characteristics, TFT LCD Module, Back Light Unit