Displayed Alarm Message

Severity

Action Required

 

 

 

Filter Sensor Fault

Warning

• A hardware failure exists. For assistance, refer to the back page of

 

 

this manual for contact information.

 

 

 

High Discharge Pressure Alarm

Critical

• For assistance, refer to the back page of this manual for contact

 

 

information.

 

 

 

Internal Communication Fault

Critical

• A hardware failure exists. For assistance, refer to the back page of

 

 

this manual for contact information.

 

 

 

Low Suction Pressure Alarm

Warning

• For assistance, refer to the back page of this manual for contact

 

 

information.

 

 

 

Rtn Air High Temp

Warning

• Make sure the Return Air threshold is set correctly in the Set Unit

(Return Air High Temperature

 

Threshlds screen.

Violation)

 

• If the problem persists, contact APC at a number on the back cover

 

 

of this manual.

 

 

 

Sply Air High Temp

Warning

• Make sure the Supply Air threshold is set correctly in the Set Unit

(Supply air High Temperature

 

Threshlds screen.

Violation)

 

• If the problem persists, contact APC at a number on the back cover

 

 

of this manual.

 

 

 

Persistent High Discharge

Critical

• For assistance, refer to the back page of this manual for contact

Pressure Alarm

 

information.

 

 

 

Persistent Low Suction Pressure

Critical

• Indicates there were 3 Low Suction Pressure shutdowns in 30

Alarm

 

minutes. Alarms must be cleared manually.

 

 

• For assistance, refer to the back page of this manual for contact

 

 

information.

 

 

 

Rack Inlet High Temperature

Critical

• Make sure the Rack Inlet High Temperature Threshold is set

Violation

 

correctly in the "Thresholds" screen.

 

 

• Make sure remote temperature sensor is installed correctly in the

 

 

rack inlet air stream.

 

 

• If the problem persists, refer to the back page of this manual for

 

 

contact information.

 

 

 

Rack Inlet Temperature Sensor

Critical

• For assistance, refer to the back page of this manual for contact

Fault

 

information.

 

 

 

Suction Pressure Sensor Fault

Warning

• A hardware failure exists. For assistance, refer to the back page of

 

 

this manual for contact information.

 

 

 

Suction Temperature Sensor

Warning

• A hardware failure exists. For assistance, refer to the back page of

Fault

 

this manual for contact information.

 

 

 

Water Detection Fault

Warning

• Identify the source of the leak.

 

 

• For assistance, refer to the back page of this manual for contact

 

 

information.

 

 

 

Grp Comm Fault

Critical

• Make sure the number of cooling units in the group is configured

(Group Communication Fault)

 

properly and the A-Link connections between cooling units are

 

 

correct.

 

 

• Make sure the system is receiving power and is connected properly.

 

 

• A hardware failure exists. For assistance, contact APC at a number

 

 

on the back cover of this manual.

 

 

 

InRow SC Operation

25

Page 31
Image 31
APC ACSC101, ACSC100 manual Threshlds screen

ACSC101, ACSC100 specifications

The APC ACSC100 and ACSC101 are power distribution units designed to manage and protect electronic equipment in data centers and critical infrastructure environments. Known for their reliability and efficiency, these models provide an essential solution for organizations that depend on constant power supply and equipment availability.

One of the main features of the APC ACSC100 and ACSC101 is their modular design. This flexibility allows for tailored configurations based on the user's unique requirements, making them suitable for diverse environments, from small server rooms to large-scale data centers. The units can accommodate a variety of input and output configurations, which helps in optimizing space and enhancing power management strategies.

These models are equipped with advanced technologies that enhance their performance. For instance, the ACSC100 and ACSC101 incorporate intelligent monitoring systems that provide real-time insights into power usage and distribution. This allows system administrators to monitor the performance remotely, ensuring that any potential issues can be addressed promptly before they escalate into more significant problems.

Another prominent characteristic of these power distribution units is their high level of protection. They come with built-in surge suppression and fault protection, safeguarding critical equipment against power surges and electrical faults. This feature is especially vital in environments where sensitive electronic components are in operation.

Moreover, the APC ACSC series incorporates energy-efficient designs. These models comply with various industry standards aimed at reducing energy consumption while maximizing output, contributing to a lower carbon footprint. Their efficiency not only helps in cutting operational costs but also aligns with sustainability goals that many organizations are striving to achieve.

User-friendly interfaces are a highlight of the ACSC100 and ACSC101. They feature intuitive LCD screens that simplify configuration and monitoring processes. This ease of use reduces the likelihood of human error during setup and operation, making them accessible even for those with limited technical expertise.

In summary, the APC ACSC100 and ACSC101 are cutting-edge power distribution solutions built for reliability, efficiency, and protection. Their modular design, advanced monitoring technology, robust safety features, energy efficiency, and user-friendly interface make them ideal choices for businesses seeking dependable power management systems in critical environments. With these models, organizations can ensure that their electronic assets are well-protected and efficiently managed, leading to enhanced operational continuity.