Function Button Quick-Reference

Function

Button

Timing

UPS

Description

(seconds)

Status

 

 

 

 

 

Power

 

 

 

 

Power On

Power Off

0.2Off

2 On

Press POWER to start receiving input utility power. If A/C input power is not available, the Back-UPS will run on battery power.

The Back-UPS is not receiving input utility power, but is providing surge protection.

Display

Status Inquiry

Full-Time/Power- Saving mode

Mute

0.2On

2 On

Verify the status or condition of the Back-UPS. The LCD will illuminate for 60 seconds.

The LCD will illuminate and the Back-UPS will beep to confirm the Full-Time mode. The LCD will darken and the Back-UPS will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the LCD will illuminate if a button is pressed, then darkens after 60 seconds of no activity.

Event Specific

0.2

On

General Status Enable/

2

On

Disable

 

 

Disable any audible alarms caused by an event.

Enable or disable the audible alarms. The Mute icon will illuminate and the Back-UPS will beep one time. The Mute function will not activate unless the Back-UPS is operating on battery power.

Sensitivity

6

Off

The Load Capacity icon will blink, indicating that the Back-UPS is

 

 

 

in programming mode. Use the POWER button to scroll through

 

 

 

Low, Medium, and High, stop at selected sensitivity. The Back-

 

 

 

UPS will beep to confirm selection. See Configuration for details.

 

 

 

 

Master/Controlled

2

On

The leaf icon will darken indicating that the Master Outlet feature is

outlet Enable/Disable

 

 

disabled or illuminate to indicate the Master Outlet feature is

 

 

 

enabled. The Back-UPS will beep once.

 

 

 

 

Master/Enable

6

On

While calibrating the threshold setting, the device connected to the

Threshold Calibration

 

 

Master Outlet should be turned off or placed in Standby or Sleep

 

 

 

mode. Upon completion, Power-Saving icon will flash 3 and beep

 

 

 

3 times.

 

 

 

 

Self-Test (manual)

6

On

The Back-UPS will perform a test of the internal battery. Note: This

 

will happen automatically when the Back-UPS is turned ON.

 

 

 

Event Reset

Fault Reset

0.2

On

When the Event screen is visible, press and hold DISPLAY, then

 

 

press POWER, to clear the utility failure event counter.

2

Fault

After a fault has been identified, press POWER to remove the

 

 

visual indication and return to standby status.

6

Back-UPS® Pro Installation and Operation

Page 6
Image 6
APC BR1300G, BR1500G manual Function Button Quick-Reference, Function Button Timing, Description, Seconds, Status

BR1500G, BR1300G, 1300 specifications

The APC 1300, BR1300G, and BR1500G are part of the APC Back-UPS series, designed to provide reliable backup power and surge protection for a variety of electronic devices. These uninterruptible power supplies (UPS) are essential for ensuring continuous operation in situations where power interruptions can lead to data loss or equipment damage.

Starting with the APC 1300, this model offers a compact design while delivering 1300 VA of power. Its internal battery provides ample run-time for critical devices, ensuring that users can save their work and safely shut down equipment during a power failure. The LCD display provides real-time information on power status, battery level, and load capacity, allowing for easy monitoring.

Next, the BR1300G enhances the capabilities of the APC series with its features tailored for home and small office environments. Delivering 1300 VA of power, it also incorporates Automatic Voltage Regulation (AVR) technology, which corrects minor voltage fluctuations without using the battery, improving battery life and ensuring consistent power delivery. The BR1300G is equipped with multiple outlets, allowing users to connect various devices, and features USB connectivity for easy management and monitoring via compatible software.

The BR1500G represents a more advanced option, providing 1500 VA of power. This model also incorporates AVR technology and offers enhanced run-time, making it suitable for larger systems. Its LCD panel provides a comprehensive overview of the UPS status, while the energy-efficient design ensures reduced power consumption. The BR1500G also boasts additional outlets, including a few which are specifically designed for high-voltage devices, making it an ideal choice for small to medium-sized businesses.

All three models feature an intuitive interface, ensuring ease of use for individuals unfamiliar with UPS systems. They are built with high-quality components that provide robust protection against power surges and spikes, which can otherwise lead to equipment damage. Moreover, the compact form factor of each UPS allows for flexible placement within any environment.

In summary, the APC 1300, BR1300G, and BR1500G deliver essential backup power solutions with advanced features and robust technologies. Their impressive specifications make them versatile options for both home and business users seeking to protect their valuable electronic devices from unforeseen power issues.