Controls and Indicators
CTSLLP/G Bottom View
Index | Control/Indicator | Definition | 
1  | Ground wire lug  | Provides connection of chassis to earth ground  | 
  | 
  | 
  | 
2  | Utility power input  | Yellow indicator illuminates when line voltage is present  | 
  | indicator lamp (not  | 
  | 
  | present on all models)  | 
  | 
  | 
  | 
  | 
3  | Normal indicator lamp  | Green indicator illuminates when the unit is operating in normal  | 
  | 
  | mode, (output is provided by CTFLM module)  | 
  | 
  | 
  | 
4  | Standby indicator  | Red indicator illuminates when the power supply has transferred  | 
  | lamp  | from normal to emergency or backup operation, (usually  | 
  | 
  | indicates loss of line voltage)  | 
  | 
  | 
  | 
5  | Entry point for utility  | Physical entry point for utility power input wiring  | 
  | power conduit – ½”  | 
  | 
  | (1.3 cm)  | 
  | 
  | 
  | 
  | 
6  | Optional second  | Coax adapter used when an optional backup CTFLM module is  | 
  | CTFLM cable adapter  | installed  | 
  | 
  | 
  | 
7  | Status monitoring  | Entry point for status monitoring connector  | 
  | connector  | 
  | 
  | 
  | 
  | 
8  | Output cable adapter  | Coax adapter for power supply output  | 
  | 
  | 
  | 