Troubleshooting

On-Screen Warning Messages

OnView Message

Recommended Action

 

 

CHANGE THE LAMP

The lamp unit should be replaced soon. Power will turn off automatically after 200 hours of

AFTER REPLACING THE LAMP,

use if you do not replace the lamp unit and reset the lamp time. See page 16.

RESET THE LAMP TIMER.

 

 

 

CHANGE THE LAMP

Replacing the lamp unit is recommended. Call ViewSonic® Customer Service to order a

AFTER REPLACING THE LAMP,

new lamp unit (RLU-150-03A). Power will turn off automatically after 20 hours of use if you

RESET THE LAMP TIMER.

do not replace the lamp unit and reset the lamp time. See page 16.

THE POWER WILL TURN

 

OFF AFTER 20 HR.

 

 

 

CHANGE THE LAMP

Replace the lamp unit now. The power will turn off after 10 minutes.

(Blinking message)

 

 

 

NO INPUT IS DETECTED

No signal input is detected. Check all cable connections to all input devices.

 

 

SYNC IS OUT OF RANGE

Check to make sure the input signal (Horizontal and Vertical frequency) is within the

range supported by the projector. See page 13.

 

 

 

Control Panel Indicators

ON Indicator

LAMP Indicator

TEMP Indicator

Meaning

Recommended Action

 

 

 

 

 

Lights orange

Goes off

Goes off

Standby mode

---------------------

 

 

 

 

 

Blinks green

Goes off

Goes off

While warming up

---------------------

 

 

 

 

 

Lights green

Goes off

Goes off

During normal operation

---------------------

 

 

 

 

 

Blinks orange

Goes off

Goes off

While cooling down

---------------------

 

 

 

 

 

 

 

 

 

Power OFF projector and let it

Lights red

Lights red

Goes off

Lamp cannot light

cool down for 45 minutes.

If LAMP Indicator is still lit,

 

 

 

 

the lamp may be defective.

 

 

 

 

Replace the Lamp Unit.

 

 

 

 

 

 

 

 

Lamp is not properly

After the lamp has cooled

 

 

 

down (45 min.), insert the

Lights red

Blinks red

Goes off

installed, or lamp door is

Lamp Unit securely and re-

 

 

 

open

 

 

 

attach the lamp cover.

 

 

 

 

 

 

 

 

 

Lights red

Goes off

Goes off

Cooling fan is not working

Contact ViewSonic Customer

properly

Support

 

 

 

 

 

 

 

 

Blinks red

Blinks red

Blinks red

Maximum number of lamp

Replace the Lamp Unit and

hours has been exceeded

reset the Lamp Time (see

 

 

 

page 16).

 

 

 

 

 

 

 

 

 

 

 

 

 

....continued

14

 

Troubleshooting