Aprilaire 1510 specifications Expand clean filter

Models: 1510

1 4
Download 4 pages 15.38 Kb
Page 3
Image 3
Expand clean filter.

INSTALLATION

1. Disconnect power to the furnace or air handler at the electrical

 

Figure 3

service panel.

 

Manual background WARNING

120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed.

2.Remove the air cleaner door from the outer housing and pull out the filtering media.

3.If replacing an existing filter, remove the filter and thoroughly clean the blower compartment.

4.Use screws (field supplied) to mount the outer housing to the furnace/air handler. There is no inlet or outlet side on the outer housing (the outer housing can be mounted on the left or right side of the furnace/air handler).

5.Mount the return ductwork to the outer housing.

6.Seal all connections using mastic, foil tape or silicone based caulk.

7.Install the filtering media (see Figure 3).

8.Install the door.

9.Reconnect power to the furnace or air handler at the electrical service panel.

Expand clean filter.

Install filter with Air Flow pointing

toward Furnace or Air Handler.

Align filter in top and bottom rails and slide into place. Reinstall door.

3

Page 3
Image 3
Aprilaire 1510 specifications Expand clean filter