TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

SYMPTOM

 

TROUBLESHOOTING PROCEDURE / POSSIBLE REASON

Dehumidifier is producing

 

• Reheat of outgoing air will cause a temperature increase across the dehumidifier.

hot air.

 

• Unit will possibly run continuously initially. After unit has “dried” home,

 

 

 

 

dehumidifier will cycle, reducing load.

 

 

 

Dehumidifier Blower is running,

 

• Normally Open Damper was used instead of Normally Closed Damper in backflow.

but no airflow.

 

• Total HVAC system static is higher than 0.8” w.c.

 

 

 

 

 

Dehumidifier not adequately

 

• Unit will need time to “dry” materials in home before effectively changing RH.

dehumidifying.

 

• Too little airflow through dehumidifier.

 

 

 

 

• Total HVAC system static is higher than 0.8” w.c.

 

 

• Compressor is not turning on.

 

 

• System undercharged.

 

 

 

Dehumidifier is not

 

• Check condensate trap to be sure it is clear.

draining properly.

 

• Check drain line for continuous slope.

 

 

 

 

 

HVAC fan does not turn

 

• Make sure there is power to the HVAC equipment.

on when cycle time dial is

 

• Check the wiring diagram for the R, C, W, Y, GH, and GS at the HVAC equipment,

in “TEST” mode.

 

 

thermostat, and the dehumidifier.

 

 

 

 

• Make sure the sensor is connected to the Outdoor Temperature Sensor terminals

 

 

or the System Setup block is set to “TIMED” mode.

 

 

• Check the voltage across the R and C terminals at the dehumidifier. Voltage

 

 

should be 18 VAC minimum - 30 VAC maximum.

 

 

• In “TEST” Mode, the HVAC fan will activate for 1 minute, DO NOT LEAVE IN TEST

 

 

MODE AS DEHUMIDIFIER WILL NOT OPERATE.

 

 

 

The dehumidifier damper does

 

• Follow all of the system checkout procedures.

not open in “TEST” Mode.

 

• Check the wiring diagram for the damper and 24 VAC transformers.

 

 

 

 

 

Fan cycling operates

 

• If the HVAC equipment is making a Heat or Cool call, or the fan is in Continuous

continuously after the dial

 

Operation, fan cycling will remain on until the requirement set by the cycle

is taken off “TEST” mode.

 

period dip switch and knob is met.

 

 

• If the interval is set at 1 HOUR and the cycle time is set at 60 minutes, fan

 

 

cycling will be on continuously. Change the setting to a lower amount if this is

 

 

not desired.

 

 

 