WHOLE HOUSE INSTALLATION AND OPERATION
In this configuration the dehumidifier will pull air from the return duct. The air passes through the dehumidifier, where moisture is removed, and then returned to the HVAC system downstream of the cooling coil in the supply plenum. This installation is used when the HVAC unit conditions the area where dehumidification is needed. Connection to the HVAC unit for the primary living space or basement HVAC unit is ideal for this installation.
REQUIRED COMPONENTS |
| OPTIONAL COMPONENTS | |
1 – 6508 Normally Closed Power Open Damper | 6506 | Ventilation Damper | |
Duct Work |
| 24 VAC Transformer (10 VA minimum) for Ventilation Damper | |
24 VAC Transformer (10 VA minimum) | 8052 | Outdoor Temperature Sensor | |
Thermostat Wire |
| Normally Closed Condensate Overflow Safety Switch |
FIGURE 3 – DUCTING |
|
|
COOLING COIL | AIR CLEANER |
|
6“ MIN | 6“ MIN |
|
SUPPLY |
|
|
AIRFLOW |
| RETURN |
|
| |
|
| AIRFLOW |
HVAC UNIT | OPTIONAL N.C. |
|
VENT CONTROL |
| |
| DAMPER |
|
| (SEE PAGES | OPTIONAL |
|
| |
|
| OUTDOOR |
|
| AIR INTAKE |
1700 | 3‘ MIN |
|
|
| |
N.C. BACKFLOW DAMPER |
|
|
|
|
4