Aprilaire 1700 Safety Instructions, Overview, Specifications, Location Notes, Weight 93 lbs

Models: 1700

1 16
Download 16 pages 3.98 Kb
Page 2
Image 2
SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS

WARNING

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock or damage to product.

120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation. Leave power disconnected until installation is completed.

Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork.

Unit weight and dropping may cause personal injury or equipment damage. Handle with care.

OVERVIEW

The purpose of the Aprilaire Dehumidifier is to keep the humidity in the house at acceptable limits to reduce the unwanted effects of high humidity. The dehumidifier will measure the dewpoint of the house to decide if it needs to run. The dryness set point can be adjusted with the control knob on the inlet side of the unit.

An integrated air cycling feature can be used to turn on the HVAC fan to cycle the air through the house to balance the indoor conditions. This feature is set up during installation based on house size and homeowner preference. An optional ventilation damper can also be installed to bring in outside air during air cycling.

SPECIFICATIONS

Dimensions: 20 3 4”W x 24”L x 20 78”H (mounting feet fully engaged) 20 3 4”W x 24”L x 22 38”H (mounting feet fully extended)

Weight: 93 lbs

Capacity: 90 pints per day @ 60%RH, 80°F (ANSI/AHAM DH-1-2003 conditions)

Power: 115 VAC, 8 Amps. Unit is equipped with an 8 ft. grounded power cord.

Design Airflow: 275 CFM @ 0.6 in. w.c.

Filter: MERV 8 Filter

Cabinet Insulation: 1” foil faced EPS insulation

Inlet Air Operating Conditions: 40°F to 105°F

Ambient Air Operating Conditions: 40°F to 150°F

LOCATION NOTES

The dehumidifier can be installed in a wide variety of locations (including unconditioned spaces), provided the ambient conditions are between 40°F and 150°F. Note the following requirements for each application:

Attic / Garage

All duct work must be insulated.

Unit should be placed in a drain pan with overflow protection to prevent water damage in the event of a drain failure.

The condensate line should be insulated to prevent condensation on the outside of the condensate line.

Precautions should be taken to assure that the unit does not operate in conditions below 40°F or above 150°F.

Basement

• Precautions should be taken to assure that the unit does not operate in conditions below 40°F.

Crawl Space

All duct work must be insulated.

The condensate line should be insulated to prevent condensation on the outside of the condensate line.

Precautions should be taken to assure that the unit does not operate in conditions below 40°F.

2

© Research Products Corporation 2005

Page 2
Image 2
Aprilaire 1700 Safety Instructions, Overview, Specifications, Location Notes, Weight 93 lbs, Attic / Garage, Basement