Aprilaire specifications MODEL 500 SERIES HUMIDIFIER, Attention Installer, Specifications

Models: 500M 500

1 2
Download 2 pages 53.65 Kb
Page 1
Image 1
ATTENTION INSTALLER:

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION

ATTENTION INSTALLER:

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.

This product must be installed in compliance with all local, state and federal codes.

Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.

 MODEL 500 SERIES HUMIDIFIER1.ELECTRICAL SHOCK HAZARD.RISK OF PROPERTY AND EQUIPMENT DAMAGE.SPECIFICATIONS2.SHARP EDGES HAZARD. Sharp3.RISK OF SCALDING. Water MODEL 500 SERIES HUMIDIFIER

RECOMMENDED WIRING DIAGRAMS WARNING

1.ELECTRICAL SHOCK HAZARD.

INSTALLATION OPTIONS CAUTION

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock.

2.SHARP EDGES HAZARD. Sharp

edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.

3.RISK OF SCALDING. Water

temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.

1.Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.

2.Do not install humidifier or bypass connection on the furnace jacket.

3.Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.

4.Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.

5.Do not connect Model 500 or 500M transformer to blower motor wiring. Premature component failure may result.

6.When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfiedto eliminate high temperatures from damaging the Humidifier Control.

7.Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.

8.Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums.

Width (including solenoid valve): 15 58

Height (including drain spud): 13”

Depth: 101 4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

9 1 2”W x 9 1 2”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC-60 Hz, 0.5 AMP

RECOMMENDED WIRING DIAGRAMS

(SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)

INSTALLATION OPTIONS

The Model 500 and 500M Aprilaire can be

installedon either the supply or return

Model 500

DIGITALHUMIDIFIER

CONTROL

R C A B

ODT W/G Cf

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 500M

MANUAL CONTROL

IMPORTANT

USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR

CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED

OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.

• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.

24 VAC FURNACE

ACCESSORY TERMINALS

OR TRANSFORMER

(10VA MINIMUM)

SHUT-OFF

plenum of a forced air handling system and is easily reversible for installation with right hand or left hand bypass duct connections. The humidifier dimensions and serviceabilitymust be considered when selecting the best location for the humidifier.Here are 2 examples of many types of installations.

Upflow

Model 500 SUPPLY

CONTINUOUSLY POWERED

24 VAC TRANSFORMER

PROVIDED WITH HUMIDIFIER

IMPORTANT

DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.

SHUT-OFF

(SADDLE VALVE)

WATER SUPPLY

(SADDLE VALVE)

WATER SUPPLY Model 500M

COMMON

YELLOW

RETURN Upflow

NORTH, EAST

OR WEST SIDE

OF HOME

OUTDOOR

TEMPERATURE

SENSOR OR

MANUAL MODE

RESISTOR

ABOVE EXPECTED

SNOW LINE

24 VAC FURNACE ACCESSORY TERMINAL

COMMON

HorizontalManual backgroundManual background YELLOW 24V SOLENOID VALVE WIRES

Manual background CONNECT DRAIN LINE HERE

CONSULT FURNACE MANUFACTURER FOR VOLTAGE AND OPERATION PARAMETERS OF ACCESSORY TERMINALS.

TERMINALS MAY BE LABELED: “HUM”, “ACC” OR “EAC”

NOTE: IF 120V, INSTALL 24V TRANSFORMER.

NOTE: SEE CONTROL INSTRUCTIONS FOR OTHER

HI

 

24V SOLENOID

 

 

VALVE WIRES

LO

 

 

FURNACE

 

 

BLOWER MOTOR

 

 

 

MODEL 50

 

 

CURRENT

CONNECT DRAIN LINE HERE

 

SENSING RELAY

 

 

 

(IF REQUIRED)

 

IMPORTANT

WHEN MODEL 50 CURRENT SENSING RELAY IS USED:

WIRE MODEL 50 CURRENT SENSING RELAY INTO 24 VAC HUMIDIFIER CONTROL CIRCUIT ONLY!

DO NOT INSTALL IN TRANSFORMER PRIMARY CIRCUIT.

Horizontal

RETURN

Manual background SUPPLY

90-1079

NOTE

When installing Aprilaire humidifier on a heat pump system, use hot

WIRING OPTIONS.

90-1204

90-1207

water. The heated water supplements the reduced supply air temperature as added heat for evaporation.

RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357