Operating Instructions and Parts Manual
Installation and Operation | unplug power cord and proceed | f. Replace the gasket making sure |
(Continued) | to maintenance guideline item 4 | the openings are aligned. |
| in this section. | g. Replace the volute cover. |
TSC130 PRO
Para Piezas de Repuestos, Llame al 1-877-278-2797
! DANGER
Do not handle pump with wet hands or when standing in
water or on a damp surface when the unit is operating or fails to operate. Always disconnect pump power cord from power source before handling.
6.Plug the power cord into a ground- ed
7.The pump will remove water down to 1/8 inches of the hard surface the pump was placed on.
8.The pump should be turned off once the water level reaches the
|
| Do not allow |
! NOTICE |
| |
| pump to run dry. |
The shaft seal depends on water for lubrication. Operating pump without water will damage the shaft seal and cause pump failure.
Maintenance
! DANGER
Always disconnect electric supply before attempting to install, service, relocate or per-
form any maintenance. Failure to do so could result in fatal electrical shock.
Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines:
1. The motor housing of the pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock.
2.Verify pump is operating correctly.
a.Disconnect pump from power source.
b.Disconnect discharge hose from pump.
c.Immerse pump in a bucket or tub of water.
d.Plug power cord into a grounded 115 volt AC power outlet. If pump operates correctly proceed to step #3. If pump does NOT operate,
3. Verify discharge hose is correctly | h. Replace the 3 screws. | |
installed. | ||
| ||
a. Connect hose to another water |
| |
source such as a faucet. If water |
| |
flows through hose, proceed to |
| |
step 3b. If water is restricted, veri- |
| |
fy discharge hose is unwound. |
| |
Remove all kinks, bends or |
| |
obstructions in hose. |
| |
b. Verify pumping height does NOT |
| |
exceed 25 feet (See Figure 1). If |
| |
pumping height is greater than |
| |
25 feet, this pump will NOT work. |
|
4.Periodic cleaning of pump is required to maintain performance of the pump. Follow the cleaning steps listed below:
a.Unplug the power cord.
b.Remove the 3 screws at the bot- tom of the pump.
c.Remove the volute cover. Note the alignment marks.
d.Remove the gasket. Note how the openings in the gasket align with the openings in the pump base.
e.Remove the debris and make sure the impeller turns freely.
25 Ft. Max.
Water Level
Figure 1 Water Level
Sírvase proporcionar la siguiente información: | Envíe su solicitud de repuestos a la siguiente direccion: |
- Número de modelo | Aqua Pro Systems |
- Número de serie (si tiene) | 101 Production Drive |
- Descripción y número de repuesto como se muestra | Harrison, OH 45030 U.S.A. |
en la lista de repuestos |
|
1
23
45
6
No. de | Descripción |
|
|
Ref. | TSC130 PRO | CTD. | |
1 | Cordón eléctrico | 1 | |
2 | Empalme de descarga | 1 | |
3 | Carcasa exterior con |
|
|
| junta tórica | 1 | |
|
| 1 | |
4 | Impulsor | 23097 | 1 |
5 | Junta del espiral | 23122 | 1 |
6 | Cubierta del difusor con rejilla | 1 |
2 | 7 Sp |