AquaPRO TSC130 PRO Para Piezas de Repuestos, Llame al, Maintenance, Continued, No. de, 7 Sp

Models: TSC130 PRO

1 4
Download 4 pages 4.92 Kb
Page 2
Image 2
(Continued)

Operating Instructions and Parts Manual

Installation and Operation

unplug power cord and proceed

f. Replace the gasket making sure

(Continued)

to maintenance guideline item 4

the openings are aligned.

 

in this section.

g. Replace the volute cover.

TSC130 PRO

Para Piezas de Repuestos, Llame al 1-877-278-2797

! DANGER

Do not handle pump with wet hands or when standing in

water or on a damp surface when the unit is operating or fails to operate. Always disconnect pump power cord from power source before handling.

6.Plug the power cord into a ground- ed 115-volt AC power outlet. The pump will start operating as soon as the power cord is plugged into the power outlet.

7.The pump will remove water down to 1/8 inches of the hard surface the pump was placed on.

8.The pump should be turned off once the water level reaches the 1/8-inch mark.

 

 

Do not allow

! NOTICE

 

 

pump to run dry.

The shaft seal depends on water for lubrication. Operating pump without water will damage the shaft seal and cause pump failure.

Maintenance

! DANGER

Always disconnect electric supply before attempting to install, service, relocate or per-

form any maintenance. Failure to do so could result in fatal electrical shock.

Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines:

1. The motor housing of the pump is completely sealed TSC130 PRO and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock.

2.Verify pump is operating correctly.

a.Disconnect pump from power source.

b.Disconnect discharge hose from pump.

c.Immerse pump in a bucket or tub of water.

d.Plug power cord into a grounded 115 volt AC power outlet. If pump operates correctly proceed to step #3. If pump does NOT operate,

3. Verify discharge hose is correctly

h. Replace the 3 screws.

installed.

 

a. Connect hose to another water

 

source such as a faucet. If water

 

flows through hose, proceed to

 

step 3b. If water is restricted, veri-

 

fy discharge hose is unwound.

 

Remove all kinks, bends or

 

obstructions in hose.

 

b. Verify pumping height does NOT

 

exceed 25 feet (See Figure 1). If

 

pumping height is greater than

 

25 feet, this pump will NOT work.

 

4.Periodic cleaning of pump is required to maintain performance of the pump. Follow the cleaning steps listed below:

a.Unplug the power cord.

b.Remove the 3 screws at the bot- tom of the pump.

c.Remove the volute cover. Note the alignment marks.

d.Remove the gasket. Note how the openings in the gasket align with the openings in the pump base.

e.Remove the debris and make sure the impeller turns freely.

25 Ft. Max.

Water Level

Figure 1 Water Level

Sírvase proporcionar la siguiente información:

Envíe su solicitud de repuestos a la siguiente direccion:

- Número de modelo

Aqua Pro Systems

- Número de serie (si tiene)

101 Production Drive

- Descripción y número de repuesto como se muestra

Harrison, OH 45030 U.S.A.

en la lista de repuestos

 

1

23

45

6

No. de

Descripción

 

 

Ref.

TSC130 PRO

CTD.

1

Cordón eléctrico

31006-005

1

2

Empalme de descarga

15875-002

1

3

Carcasa exterior con

 

 

 

junta tórica

28053-001

1

 

 

19023-001

1

4

Impulsor

23097

1

5

Junta del espiral

23122

1

6

Cubierta del difusor con rejilla

28056-002

1

2

7 Sp
Page 2
Image 2
AquaPRO TSC130 PRO Para Piezas de Repuestos, Llame al, Maintenance, Continued, No. de, Descripción, 7 Sp, Danger