Code if vent will have elbows or share venting with another appliance.

The vent connector should have as much vertical rise as possible (minimum 12”) before any horizontal run. Optional powervent available in order to sidewall vent. Contact your local dealer. The appliance must be located as close as practicable to a chimney or vent. The vent pipe sections must be secured to each other with sheet metal screws. Keep in mind the minimum clearance from the top of your heater. Remember also that single wall vent pipe connectors require a 6 inch clearance from combustibles. National Fuel Gas Code specifies double wall — Type “B”

vent pipe be used in cold climates and for gas vents running through attics. We consider double wall vent pipe preferable in all circumstances. Any vent section greater than 45 degrees from vertical is considered horizontal. Horizontal sections of vent connectors must slope upwards at least 1/4 inch for every foot of its horizontal length. Keep the horizontal section short and avoid too many elbows. Optional power vent available in order to sidewall vent. Contact your local dealer.

To check the draft:

Close all doors and windows to the outside.

Turn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc.

Open all doors between the AquaStar and these other ap- pliances.

Run the unit for at least 10 minutes. Then hold an ordinary mirror at the side above the front shell. Any flue gases backdrafting will cause the mirror to fog. This is a serious health hazard and must be corrected. Poor venting can result in soot building up inside the heater, overheating of the heater and freezing of the heat exchanger in a freezing environment.

The mirror will remain clear with a properly functioning draft.

WARNING

Note: The burners of an instantaneous “on demand” water heater such as the AquaStar are only on at the time that hot water is actually being used, the vent pipe is therefore cold except for the short durations when hot water is being used, it is therefore very important that the venting and air supply be adequate to provide a good positive draft as soon as the burners turn on. See venting guide on back page.

The AquaStar 125BL instantaneous water heaters have built- in draft diverters and are designed for indoor installation only. The draft diverter outlet must be connected to a clear, unobstructed vent of the same size, or larger.

In Canada, CAN/CGA-B149 Installation Code for detailed requirements

In U.S.A., ANSI Z223.1 - NFPA 54, national Fuel Gas Code for detailed requirements.

The vent connection for the AquaStar 125BL is 5 inches. However, in CANADA, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws. See figure 3.

5” X 6” ADAPTOR

USED ON HIGH ALTITUDE

Fig. 3 - Vent Adaptor for High Altitude Canadian

Installations

WARNING: Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void CSA Certification.

GAS CONNECTIONS and Gas Regulator

NOTE: The Aquastar 125 BL is supplied with a gas pressure regulator that must be installed on the heater before attaching the gas supply line. See figure 4. Failure to install the gas regulator as shown in figure 4 will be a violation of CSA certification of the unit. The regulator supplied with the heater is preset for the gas shown on the rating plate to the correct pressure. It is an appliance level regulator designed for (low inlet) pressure (less than 1/2 Psig or 15” W.C.) DO NOT connect to an unregulated or high pressure propane line or to a high pressure commercial natural gas line.

GAS INLET PIPE

PRESSURE TAP

PLASTIC VENT CAP

PRESSURE REGULATOR (with directional arrow on reverse side pointing upward)

Fig. 4 - Installation of Gas Pressure Regulator

The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure (as indicated on the rating plate and in the manual for altitude up to 2000 feet (660 meters) above sea level. On appliances being installed above 2000 ft (660 meters) elevation, the inlet gas pressure should be set at installation to the value shown below.

7

Page 7
Image 7
AquaStar 125B NGL, 125B LPL specifications GAS Connections and Gas Regulator, To check the draft

125B NGL, 125B LPL specifications

The AquaStar 125B LPL and 125B NGL are innovative products designed to meet the growing demands of modern aquaculture and water treatment facilities. Equipped with advanced features and technologies, these models are engineered for efficiency, performance, and sustainability, making them essential tools for aquaculture professionals and facility managers alike.

One of the standout characteristics of the AquaStar 125B series is its enhanced filtration system. Both the LPL (Low Pressure Liquid) and NGL (Natural Gas Liquid) models incorporate a high-capacity filter that effectively removes particulate matter and impurities from water. This ensures higher water quality and promotes healthier aquatic life. The filtration system is designed for easy maintenance, allowing operators to perform routine cleanings without downtime.

In addition to filtration, the AquaStar 125B series boasts a state-of-the-art aeration system. Efficient oxygenation is crucial for aquatic organisms, and these models utilize fine bubble diffusers to maximize oxygen transfer rates. This technology not only ensures that fish and other aquatic species thrive but also minimizes energy consumption, ultimately reducing operational costs.

Both models feature robust, corrosion-resistant materials, enhancing their durability in challenging environments. The casing is designed to withstand exposure to wet and humid conditions, ensuring longevity and reliability in various operational scenarios. Furthermore, the AquaStar 125B series incorporates energy-efficient motors, promoting reduced power consumption and minimizing the environmental impact.

Another innovative aspect is the intelligent monitoring system integrated into both models. The digital interface provides real-time data on water quality parameters, such as pH levels, temperature, and dissolved oxygen content. This allows for proactive management and immediate adjustments when necessary, ensuring optimal conditions for aquatic life.

Safety is also a key consideration with the AquaStar 125B series. Both models feature built-in safety protocols, including automatic shutoff mechanisms and alerts for abnormal readings, further reinforcing their reliability in managing aquatic environments.

In summary, the AquaStar 125B LPL and 125B NGL represent a leap forward in aquaculture technology, combining advanced filtration, aeration systems, and smart monitoring features. Their durable design and energy efficiency make them suitable for both commercial and non-commercial applications. These models not only improve water quality but also enhance the overall productivity of aquaculture operations while being mindful of environmental sustainability.