AquaStar 125FX NG, 125FX LP specifications Features, Unpacking The Aquastar Heater

Models: 125FX NG 125FX LP

1 24
Download 24 pages 10.72 Kb
Page 2
Image 2
FEATURES

Principle of Operation:

When a hot water faucet is opened, the flow of water through the heater causes the gas valve to open. At the same time a microswitch is activated which sends a spark to the pilot. The flame sensor confirms that the pilot has been lighted and allows the first two burners to ignite. The flame sensor confirms correct activation and all burners ignite. The pilot goes out. The power exhaust system runs as long as the burners are on. The heat exchanger coils absorb the heat generated by the burners and transfer heat to the water. When the hot water faucet is shut off, the gas valve automatically closes and the burners turn off, followed immediately by the exhaust system. Your hot water faucet is an ignition key to turn on the water heater, giving you control over your hot water energy use. Every time you turn off your hot water faucet, the energy consumption for hot water returns to zero.

FEATURES

-Electronic Pilot Ignition

-On/Off switch to activate system

-Power Venting with safety shutoff

-High Quality Materials for Long Working Life.

-Copper heating coils for endless supply of hot water.

-Burner output proportional to hot water flow demand for maximum energy efficiency.

-Safety flame sensor at pilot burner.

-Automatic overheating protection shut-off sensor.

-Stainless steel burners with stabilized blue flame.

-Built-in corrosion resistant power venter.

-Compact space saver: mounts on a wall with two hooks.

-Easily removable one-piece cover.

-Easy one person installation.

-Adjustable water flow restrictor to ensure that water flow demand will not exceed the heating capacity of the heater.

UNPACKING THE AQUASTAR HEATER

AquaStar 125FX LP and 125FX NG Specifications

 

AQ125FXNG

AQ125FXLPG

 

 

 

max.

130 000 Btu/hr

125 000 Btu/hr

Gas input

 

 

 

 

min.

28 000 Btu/hr

28 000 Btu/hr

 

 

 

Water Connection 1/2” Thread fitting NPT

H x W x D 29 3/4” x 18 1/4” x 8 3/4"

 

Vent 4”

 

Gas Connection 1/2” NPT thread

 

Min. Water Pressure 18 Psi

 

Max. Water Pressure 150 Psi

 

Shipping Weight 50.6 LB

 

Net Weight 44 LB

 

2.0 GPM at 90° rise

 

4.0 GPM at 45° rise

 

Min. Water Flow 1/2 gal/min

 

120V/60Hz 1.2 Amps

 

LP GAS Supply Pressure

min. 11” W.C.

(before Aquastar regulator)

max.14” W.C.*

Required LP GAS pressure at inlet

 

tap while Aquastar is operating:

10.5” W.C.

LP GAS Burner Manifold pressure while

 

Aquastar is operating at maximum input:

9.9” W.C.

Natural Gas Supply Pressure

min.: 7” W.C.

(before Aquastar regulator)

max.: 14”W.C.*

Required Natural Gas Pressure at

 

inlet tap while Aquastar is operating:

5.7”W.C.

Natural Gas Burner Manifold pressure while

Aquastar is operating at maximum input:

5.38” W.C.

*Inlet gas pressure before Aquastar regulator must not exceed this value. Pressure may need to be adjusted for high altitudes, see page 10.

This heater is packed securely. The box includes one water connection fitting, a control knob, a gas pressure regulator, a pressure relief valve, an incandescent particle tray, two hooks for hanging the heater, this manual and a warranty registration card. Do not lose this manual as there is a charge for replacement. Please complete and return the enclosed warranty registration card. The FXHOOD horizontal vent terminator is supplied separately from the 125FX water heaters. There is a set of installation instructions in the FXHOOD box.

2

6 720 606 601

Page 2
Image 2
AquaStar 125FX NG, 125FX LP specifications Features, Unpacking The Aquastar Heater