4”single wall venting only. Use stainless steel
HORIZONTAL SIDE WALL
*Maximum 15 feet with 2 elbows. Deduct 5 feet for each additional elbow.
Approved Vent Terminal
(FXHOOD or other approved terminal)
The FXHOOD is design approved with the Aquastar 125FX and has a built in back draft flapper to prevent negative air from freezing the Aquastar – see Fig. 5 for restrictions in location of vent terminal.
4”single wall venting only. Use stainless steel
Approved Vent Terminal
(FXHOOD or other approved terminal)
The FXHOOD is design approved with the Aquastar 125FX and has a built in back draft flapper to prevent negative air from freezing the Aquastar – see Fig. 5 for restrictions in location of vent terminal.
connection must be properly sealed.
G181_274
Fig 4: Some Venting Guide Suggestions
An approved side wall vent terminal must be used when the water heater is vented through a side wall. Locate in accordance with ANSI Z223.1 and local applicable codes. See Fig 5 for restrictions in location of vent terminal in relation to opening doors and windows, grade, and forced air inlets. Be certain that snow and ice will not interfere with the vent.