AquaStar 125HX NG, 125HX LP specifications General Rules to Follow For Safe Operation

Models: 125HX LP 125HX NG

1 24
Download 24 pages 47.96 Kb
Page 5
Image 5

GENERAL RULES TO FOLLOW

FOR SAFE OPERATION

1.You should follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.

2.Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.

3.The place where you install the heater must have enough ventilation. The National Fire Codes do not allow gas fired water heater installation in bathrooms, bedrooms or any occupied rooms normally kept closed. See the section below on locating the heater.

4.You must vent your heater. See section on VENTING, Page 7.

5.The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or more than 1/2 Psig (3.5Kpa). The appliance and its gas connection must be leak tested before placing the appliance in operation.

6.Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material which might burn.

7.Correct gas pressure is critical for the optimum operation of this heater (see specifications on page 2). Gas piping must be sized to provide the required pressure at the maximum output of the heater, while all the other gas appliances are in operation. Check with your local gas supplier, and see the section on connecting the gas supply.

8.Should overheating occur or the gas supply fail to shut off, turn off the gas supply at the manual gas shut off valve on the gas line.

9.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

PROPER LOCATION FOR INSTALLING YOUR HEATER

The heater may still operate even when improperly vented. It will, however, be less efficient and could eventually damage the heater. It could even result in human sickness or death due to oxygen deprivation and carbon monoxide poisoning. Follow the guidelines below:

1.Place your heater as close to a vent or chimney as possible.

2.National building codes require that you do not install this appliance in bathrooms, bedrooms or any occupied rooms normally kept closed.

3.Simultaneous operation of other appliances such as exhaust fans, ventilation systems clothes dryers, fireplaces or wood stoves could create a vacuum effect in your home which could cause dangerous combustion by-products to spill back into your home rather than venting to the outside through the flue. Confirm that your 125 HX is venting properly when all these other appliances are running. See section on venting.

Do not obstruct the flow of combustion and ventilation air to the appliance. If installed near a clothes dryer it is very important that the dryer be properly vented. Failure to properly vent a dryer could result in a gradual accumulation of lint on the water heater fin coils and burners, leading to a dangerous condition of vent blockage and poor unsafe combustion.

4.Your hot water lines should be kept short to save energy. It is always best to have hot water lines insulated.

5.This product is neither designed nor approved for outside installations. This product is not approved for manufactured homes (mobile home), recreational vehicles (RV) or boats. Reference ANSI Z21.10.3.

WARNING: The water in this water heater is cold and always remains cold except for the times that hot water is

being used DO NOT INSTALL IN AN AREA WHERE IT COULD FREEZE.

This heater is neither designed for nor approved for outside installation.

Drain the heater entirely if freezing temperatures are anticipated in area where heater is installed by disconnecting both the inlet and outlet water connections from the heater (disconnect the outlet flex line from where it connects to the copper heat exchanger). Additionally remove the drain plug under the water valve. See Fig. 1.

Carefully select the location of your new heater. For your

safety and for proper heater operation, you must provide anFig. 1 - Water heater drain plug abundant supply of combustion air and a proper venting.

6 720 606 804

5

Page 5
Image 5
AquaStar 125HX NG, 125HX LP General Rules to Follow For Safe Operation, Proper Location for Installing Your Heater

125HX LP, 125HX NG specifications

The AquaStar 125HX NG and 125HX LP are highly efficient gas tankless water heaters designed to meet the demands of modern households. With their compact size and advanced technology, these units provide an endless supply of hot water while maintaining energy efficiency. Both models cater to natural gas and propane applications, making them versatile options for various installations.

One of the standout features of the AquaStar 125HX series is its ability to deliver a powerful output of up to 199,000 BTUs, ensuring that multiple hot water outlets can operate simultaneously without a drop in temperature. Users can enjoy the convenience of hot showers, laundry, and dishwashing all at once, making it an ideal choice for busy families or households with high hot water needs.

These models incorporate a sophisticated modulating gas valve that adjusts the gas flow based on the demand for hot water. This technology not only optimizes energy consumption but also contributes to extended unit life by minimizing wear and tear on the components. The AquaStar 125HX units also come equipped with a patented electronic ignition system, which eliminates the need for a standing pilot light and reduces gas consumption.

Furthermore, the AquaStar 125HX NG and 125HX LP feature a durable heat exchanger constructed from high-grade copper, which enhances thermal efficiency and prevents corrosion. This ensures a longer lifespan and increased reliability for homeowners. Additionally, the units are compact and wall-mounted, allowing for flexible installation in various spaces, including tight utility closets or outside walls.

Safety is also a top priority, with built-in overheat protection and a freeze protection feature that ensures the unit remains operational even in colder climates. The AquaStar 125HX series operates quietly, allowing users to enjoy the benefits of hot water without the disruptive noise commonly associated with traditional water heaters.

In summary, the AquaStar 125HX NG and 125HX LP are leading choices in the tankless water heater market, combining efficiency, reliability, and innovation. Their impressive output, advanced technologies, and compact design make them suitable for modern living, ensuring homeowners have access to hot water whenever they need it. With these features, AquaStar continues to set a high standard in water heating solutions.