INSTALLATIONS (PSData)

CAUTION

The installation should be made by qualified service personnel or system installers according to the following instructions.

System Connections

Connection Example

Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while pictures are viewed on the monitors.

Camera No. 5

Camera No. 6

Camera No. 7

Camera No. 8

Camera No. 4

Camera No. 1

 

Camera No. 2

 

Camera No. 3

VS/VD INPUT

VS/VD OUTPUT

Unit Address 2

Unit Address 1

WJ-MP204C

IN

4

3

2

1

IN

IN

OUT

4

3

2

1

OUT

OUT

 

 

CAMERA

 

SPOT

 

VS/VD

ALARM / REMOTE

IN

4

3

2

1

IN

IN ALARM / REMOTE

 

SD

RD

 

 

 

 

 

 

 

T

R

 

G B

A B

A

SIGNAL GND

 

 

 

 

 

G B A B

A

SIGNAL GND

 

 

 

OUT

4

3

2

1

OUT

OUT

 

 

RS485

DATA

MODE

 

CAMERA

 

SPOT

VS/VD

RS485

DATA

MODE

WJ-MP204C

MODE

MODE

4-Line

Termination ON

 

4-Line

 

Termination OFF

VD OUT

Panasonic Security

Data mode

 

Panasonic Security Data mode

WJ-FS316

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM/REMOTE

DATA

CAMERA

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW IN

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

MULTI

 

SPOT OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLAY IN REC OUT SCREEN OUT

 

 

 

 

 

Unit Address 3

 

 

 

 

 

PLAY

 

 

 

PLAY IN

 

 

 

VIDEO IN

 

 

 

REC OUT

 

 

 

 

REC)(EXT CLICK-JOG LEFT-JOG

RIGHT-JOG G SEARCHALARM STEP

REW/FF STOP/SETUP PLAY REC G OUT IN OUTPLAY OUTREC OUTOFFAUTO

OUTENDDISK OUT IN

G RECALL OUT OUTRECOVER INRESET IN

POWER

IN

 

IN

 

 

 

 

ON

 

WJ-HD100 OUT

 

 

 

 

 

 

SIGNAL GND

 

OUT

 

 

 

 

OFF

 

AUDIO

CAMERA

VIDEO MONITOR OUT RS-232C

DATA MODE

REMOTE

TIME

SERIES

ALARM

 

SW OUT

 

 

(PLAY)

 

 

ADJUST

RECORD

 

 

 

 

Branch

Unit Address 4

 

 

 

 

 

Cable

 

 

 

 

 

 

Monitor No. 1

Monitor No. 2

Up to four WV-CU360C can be used in a system.

RS-485 Cable

6-conductor Modular Cable (supplied)

1

 

 

6

 

 

CONTROLLER No. MODE

DATA

DC 9V IN

 

 

 

 

 

 

 

 

 

 

 

 

 

Keep in OFF position

 

 

 

 

 

 

 

 

 

 

 

 

 

Termination ON

Controller No. 1

 

 

 

 

 

 

 

 

 

 

Set to OFF position

 

 

 

 

 

 

 

 

 

 

(for operator mode)

9

0

1

 

 

 

 

 

 

 

 

 

 

Keep in OFF position

 

 

 

 

 

 

 

 

 

 

8

 

2

 

 

 

 

 

 

 

 

 

 

 

7

 

3

 

 

 

 

 

 

 

 

 

 

 

6

5

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER No.

 

 

 

 

 

 

 

 

 

 

 

 

Refer to DIP switch setting on page 15

 

 

 

 

Video Signal

RS-485 Signal

(Panasonic Security

Data Mode)

13

Page 13
Image 13
Panasonic WV-CU360C manual Installations PSData, System Connections, Connection Example