DATA Port Connection (For Multiplexer)

Data ports are connected with RS-485 cables among devices using the Camera Communication protocol as follows.

Note: When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication.

• Internal Diagram

 

No.

Data Flow

Name

No.

 

 

 

 

 

 

TX (B)

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

GND

1

Controller end

 

 

2

WJ-FS616C

WV-CU360C

TX(B)

2

1

TX (A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

WJ-FS616C

WV-CU360C

TX(A)

3

 

 

 

 

 

 

RX (B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

WJ-FS616C

WV-CU360C

RX(B)

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

5

WJ-FS616C

WV-CU360C

RX(A)

5

 

 

 

 

 

 

RX (A)

6

 

 

 

 

 

 

 

6

 

GND

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Basic Connection

Video Multiplexer

WJ-FS616C

DATA

OUTIN

TERM.

OFF ON

System Controller

WV-CU360C

DATA

Termination:Termination:

ONON

RS-485 Cable

DIP Switch Setting (For Multiplexer)

An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an asterisk *.

0

12

78

3

65

 

CONTROLLER No. MODE

DATA

DC 9V IN

 

Function

 

SW position

 

 

 

 

 

OFF

 

ON

 

 

 

 

 

 

 

 

Bit 1

Unit Version

See Unit Version*

 

 

 

 

 

 

 

Bit 2

Unit Version

See Unit Version*

 

 

 

 

 

 

 

Bit 3

Unit Version

See Unit Version*

 

 

 

 

 

 

 

Bit 4

Reserved

Fixed to OFF*

 

Not used

 

 

 

 

 

Bit 5

Line termination

Off

 

On*

 

 

 

 

 

Bit 6

Operation mode

Operator*

 

Administrator

 

 

 

 

 

Bit 7

Reserved

Fixed to OFF*

 

Not used

 

 

 

 

 

Bit 8

Data transmission

Fixed to OFF*

 

Not used

 

 

 

 

 

44

Page 43
Image 43
Panasonic WV-CU360C manual DIP Switch Setting For Multiplexer, Data Port Connection For Multiplexer