MODE Switch Setting for System Example 2

The MODE switch needs to be set prior to operating a sys- tem connected as shown in Example 2.

OFF

ON

1 2 3 4 5 6 7 8

Bit 3 should be set to OFF.

Bit 5 should be set to OFF when the controller is placed in an intermediate position, or set to ON when it is con- nected at the chain end.

Controller Number Setting (PS Data)

A 10-position rotary switches provided on the rear for spec- ifying the unit number of the WV-CU360C controller in a PS Data system.

1.Remove the DC plug from the rear of the controller.

2.Use a screw driver to rotate the switch so that the arrow comes to the number you wish.

9

0

1

8

 

2

7

 

3

6

5

4

 

CONTROLLER No.

3. Connect the DC plug to the controller.

Controller No. Switch of WV-CU360C

Controller No.

 

 

0

Reserved

 

 

1

1

 

 

2

2

 

 

3

3

 

 

4

4

 

 

5

5

 

 

6

6

 

 

7

7

 

 

8

8

 

 

9

Reserved

 

 

Notes:

Set the switch to #1 when a single controller is used in the system.

Specify a unique number for each controller when con- necting multiple controllers in the system. One con- troller within the multiple controller system must be assigned the number 1.

Positions #0 and #9 are reserved and cannot be used.