■Login/Logout
●Log In
Right after powering up, the controller will be operable with- out password entry, provided user password certification is set to Off in the setup menu.
When set to On, you will be prompted to enter your regis- tered password. The default password is “12345”, but you need to remember the password assigned to you by your system administrator.
1.Insert the DC plug into the DC 9 V IN jack and connect the AC adapter to an AC outlet.
2.The controller number, software versions and [LogIn] appear in that order on the LED display.
The LOGIN indicator lights up. The controller is now operable unless password certification is activated. If it is not activated, proceed as follows.
3.Press the CAM/SET button.
4.Enter a
5.Press the CAM/SET button.
6.If password entry for user authorization has been suc- cessful, the LOGIN indicator lights up.
The unit assigned to the UNIT A/UNIT button as number 1 is selected automatically.
If password entry has failed, [Error] appears on the dis- play. The display returns to [LogIn].
●Log Out
1.Press the MON/ESC and CAM/SET buttons for about 2 seconds simultaneously.
2.[LogIn] appears on the display and the LOGIN indicator goes off.
3.Disconnect the DC plug from the controller, and remove the AC adapter from the AC outlet.
Note: If the power is not turned off after logout, the alarm indicator and alarm suspend indicator will display the same status as in normal operation.
SET | ESC |
Ready for user password entry | |
User password entry | Blink |
|
Certification
SET | off |
Authorized
The unit that is assigned to the UNIT A/UNIT button as number 1 is selected automatically.
OPERATE LOGIN ALARM
Lights after authorization
Goes off after logout
Unauthorized