Camera Cleaning

This menu is for specifying the order in which combination cameras connected to the system are cleaned.

The camera cleaning function causes cleaning of the built- in slip rings that conduct electric signals while moving the pan/tilt head. All combination cameras connected to the system are cleaned in the order specified here. Picture viewing is disabled during the cleaning process.

1.Display [CLEAn] and press the CAM/SET button. The LED displays [no-01].

2.Use the numeric buttons to enter the number of the camera where cleaning is to start.

The default setting is no-01.

Available camera numbers: 01-199

3.Press the CAM/SET button to start cleaning.

Two animated digits appear in the left part of the LCD while the digits at right display the number of the cam- era being cleaned.

When cleaning is finished, the number of the last cam- era cleaned is displayed without animation.

4.Press the ESC button to go back to the previous menu.

Unit Connection Test

This menu is for specifying the order in which data commu- nication between system units is tested prior to operating the system as a whole.

1.Display [UtESt] and press the CAM/SET button. The LED displays [01-on] or [01-oF].

2.Enter the 2-digit unit number you wish to start with.

3.Press the CAM/SET button to start the test.

The digits in the left part of the LCD display the unit number under test while 2 animated digits appear at right.

To stop the test in progress, press the CAM/SET button. When testing is finished, the number of the last unit test- ed is displayed without animation.

4.Press the CAM/SET button. Enter a 2-digit number(e.g., 01), then press the CAM/SET button.

You can now confirm the test results of a specific unit. When Off is displayed, check connections, switch set- tings, etc., of the system unit.

01-on:On, unit 01 is connected.

01-oF:Off, unit 01 is disconnected.

5. Press the ESC button to go back to the previous menu.