SCSI Commands

LOG SENSE Command (4Dh) (continued)

Table 5–26 TapeAlert Flags, Severity Levels, and Meanings (continued)

Flag

 

Severity Level *

Meaning

 

 

 

 

22

Expired Cleaning

Critical

The cleaning cartridge that was used has expired. Wait for

Media

 

all tape drive operations to complete, then use a valid

 

 

 

cleaning cartridge for cleaning.

31

Hardware B

Critical

The tape drive may have a hardware fault. Contact a service

 

 

 

representative.

32

Interface

Warning

The drive has identified a problem with the interface

 

 

 

to/from the host.

34

Download Fail

Warning

The attempted firmware download has failed.

40

Loader

Critical

The mechanism that loads media to the tape drive is

Hardware A

 

experiencing problems communicating with the tape drive.

42

Loader

Warning

The loader mechanism has experienced a hardware-related

Hardware B

 

fault.

43

Loader Door

Critical

The attempted operation has failed: the library/autoloader

 

 

 

door is not closed completely.

*Severity levels are Informational, Warning, and Critical. Informational flags provide a status-type message, Warning and Critical flags indicate that user intervention and/or service call may be required.