Quantum Instruments DLT 7000 manual TapeAlert Page Format Descriptor Data Format

Models: DLT 7000

1 312
Download 312 pages 23.26 Kb
Page 227
Image 227

SCSI Commands

MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)

5.10.3.7 TapeAlert Page (1Ch)

The TapeAlert configuration settings can be read via the MODE SENSE command’s TapeAlert Page.

Bit

7

6

 

5

 

4

3

 

2

 

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

0

PS (0)

0

 

 

 

 

Page Code (1Ch)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Additional Page Length (0A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Perf

 

 

Reserved

 

 

DExcpt

 

Test

 

Rsvd

LogErr

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

Reserved

 

 

 

 

 

MRIE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

4 – 7

 

 

 

 

 

Interval Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

8 – 11

 

 

 

Report Count / Test Flag Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

Figure 5–59 TapeAlert Page Format Descriptor - Data Format

Quantum DLT 7000 Tape System

5-123

Page 227
Image 227
Quantum Instruments DLT 7000 manual TapeAlert Page Format Descriptor Data Format