SCSI Commands

INQUIRY Command (12h) (continued)

Table 5–9 Standard Inquiry Data Page - Field Descriptions (continued)

Field Name

Value

Description

 

 

 

Sync

1

The drive supports Synchronous Data Transfers.

Linked

1

Linked Commands are supported.

CmdQue

0

The drive does not support Tagged Command Queuing.

SftRe

0

The drive implements the hard reset option in response to

 

 

assertion of the SCSI Bus reset line.

Vendor Identification

 

The value in this field is QUANTUM (there are spaces after the

 

 

word Quantum)

Product Identification

 

The value in this field is DLT 7000 (there are spaces after the

 

 

word DLT 7000)

Product Revision Level

 

This field contains 4 bytes of ASCII data that provides the

 

 

drive’s software revision levels. The first two bytes are the

 

 

version number of servo code. The second two bytes are the

 

 

version number of the SCSI/read/write code. When a firmware

 

 

update is performed on the DLT drive, this part of the revision

 

 

level will change to reflect that update (quotation marks will

 

 

not appear).

Vendor Specific

 

See Section 5.4.2 for details.

NOTE: Vendor Information, Product Identification, and Product Revision Level are returned as shown in Figure 5–5.

5.4.2 Vendor Unique Inquiry Data

The following information can be used to precisely identify the revision of subsystem components.

Quantum DLT 7000 Tape System

5-19