Quantum Instruments DLT 7000 manual Eeprom Vendor Unique Page Forced Density Example Data Format

Models: DLT 7000

1 312
Download 312 pages 23.26 Kb
Page 203
Image 203

SCSI Commands

MODE SELECT (6) / (10) Command (15h) / (55h) (continued)

An example follows that illustrates an EEPROM vendor unique page that modifies the FORCEDENSITY parameter to 4.

 

0

 

0

 

0

 

Page Code (3Eh)

 

 

 

1

 

 

 

 

Page Length (0Fh)

 

 

 

2

 

 

 

 

“F”

(46h)

 

 

 

3

 

 

 

 

“O”

(4Fh)

 

 

 

4

 

 

 

 

“R”

(52h)

 

 

 

5

 

 

 

 

“C”

(43h)

 

 

 

6

 

 

 

 

“E”

(45h)

 

 

 

7

 

 

 

 

“D”

(44h)

 

 

 

8

 

 

 

 

“E”

(45h)

 

 

 

9

 

 

 

 

“N”

(4Eh)

 

 

 

10

 

 

 

 

“S”

(53h)

 

 

 

11

 

 

 

 

“I”

(49h)

 

 

 

12

 

 

 

 

“T”

(54h)

 

 

 

13

 

 

 

 

“Y”

(59h)

 

 

 

14

 

 

 

 

“ ”

(20h)

 

 

 

15

 

 

 

 

“4” (ASCII) (34h)

 

 

 

16

 

 

 

 

<LF>

(A0h) or (00h)

 

 

 

Figure 5–46

 

EEPROM Vendor Unique Page “Forced Density” Example - Data Format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantum DLT 7000 Tape System

5-99

 

Page 203
Image 203
Quantum Instruments DLT 7000 manual Eeprom Vendor Unique Page Forced Density Example Data Format