SCSI Commands

MODE SELECT (6) / (10) Command (15h) / (55h) (continued)

 

Table 5–47

EEPROM Vendor Unique Page Parameters (continued)

 

 

 

 

 

 

 

 

 

Name

Value

Default

Length

Usage

 

 

 

 

Rep.

 

(Bytes)

 

 

 

 

 

 

 

 

 

 

 

 

ENBINQMEDCHGR

ASCII

0

1

0

= Disable media changer bit

 

 

 

 

Binary

 

 

1

= Enable media changer bit in byte 6 of

 

 

 

 

 

 

 

 

 

 

INQUIRY data (set if drive is in a media

 

 

 

 

 

changer device)

 

 

FORCECOMP

ASCII

0

1

0 = automatic 2

 

 

 

 

Binary

 

 

1

= Always compress unless front panel

 

 

 

 

 

 

 

 

 

 

selection disables it

 

 

FORCEDENSITY 1

ASCII

0

1

0 = automatic 2

 

 

 

Decimal

 

 

1

= DLT 260

 

 

 

 

 

 

 

2

= DLT 600

 

 

 

 

 

 

 

3

= DLT 2000

 

 

 

 

 

 

 

4

= DLT 4000

 

 

 

 

 

 

 

5

= DLT 2000XT

 

 

 

 

 

 

 

6

= DLT 7000

 

 

FORCEEEREBUILD

ASCII

0

1

To force all the EEPROM parameters to

 

 

Binary

 

 

reset to default, if set. WARNING: This

 

 

 

 

 

causes all Log Sense history to be reset

 

 

 

 

 

and may cause power-on hours entry to

 

 

 

 

 

be reset.

 

 

FORCEREADSILI

ASCII

0

1

To make variable READ command

 

 

 

 

Binary

 

 

handled as if the SILI bit is set if set.

 

 

HOSTCOMPSETTING

ASCII

0

1

This parameter allows the host to change

 

Decimal

 

 

the compression setting. Note that there

 

 

 

 

 

is a tradeoff between best performance

 

 

 

 

 

and best compression; if the compression

 

 

 

 

 

setting is 1 it provides the best

 

 

 

 

 

 

 

performance but the worst level of

 

 

 

 

 

 

 

compression. If the compression setting is

 

 

 

 

 

3, it provides lowest performance but

 

 

 

 

 

maximum compression. Settings for the

 

 

 

 

 

HOSTCOMPSETTING parameter are:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantum DLT 7000 Tape System

5-93

 