Quantum Instruments DLT 7000 manual Messages, Modify Data Pointer

Models: DLT 7000

1 312
Download 312 pages 23.26 Kb
Page 94
Image 94

Messages

 

Bit

7

6

 

5

 

4

 

3

 

2

 

1

 

0

 

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

Extended Message (01h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

Extended Message Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

Extended Message Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 to n-1

 

 

 

 

Extended Message Arguments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4–1 Extended Message - Data Format

 

 

 

 

 

 

 

Table 4–3 Extended Message - Field Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

 

Description

 

 

 

 

 

 

 

 

 

 

Extended Message Length

This field specifies the length, in bytes, of the Extended Message

 

 

 

 

Code plus the Extended Message Arguments that follow. Therefore,

 

 

 

 

the total length of the message is equal to the Extended Message

 

 

 

 

Length plus 2.

 

 

 

 

 

 

 

 

 

 

 

 

A value of 0 for the Extended Message Length indicates that 256

 

 

 

 

bytes follow.

 

 

 

 

 

 

 

 

Extended Message Code

The drive supports three Extended Messages. They are:

00h

 

 

 

 

MODIFY DATA POINTER

 

 

 

 

01h

 

 

 

 

 

 

 

SYNCHRONOUS DATA TRANSFER REQUEST

 

 

03h

 

 

 

 

 

WIDE DATA TRANSFER REQUEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-4

Quantum DLT 7000 Tape System

Page 94
Image 94
Quantum Instruments DLT 7000 manual Messages, Modify Data Pointer