Ariston 41-116-07 installation instructions Installation

Models: 41-116-07

1 48
Download 48 pages 48.15 Kb
Page 5
Image 5

2.INSTALLATION

2.1REFERENCE STANDARDS

2.2 SITING THE APPLIANCE

The technical information and instructions provided herein below are intended for the installer so that the unit may be installed correctly and safely.

The installation and initial start up of the boiler must be by a CORGI Registered Installer in compliance with the installation standards currently in effect, as well as with any and all local health and safety standards i.e.

CORGI .

This appliance must be installed by a competent installer in accordance with current Gas Safety (installation & use) Regulations.

The installation of this appliance must be in accordance with the relevant requirements of the current Gas Safety (installation & use) Regulations, the Local Building Regulations, the current I.E.E. Wiring Regulations, the byelaws of the local water authority, and in Scotland, in accordance with the Building Standards (Scotland) Regulation and Health and Safety document No. 635 “Electricity at work regulations 1989”.

Installation should also comply with the following British Standard Codes of Practice:

BS 7593:1992

Treatment of water in domestic hot water central

 

heating systems

BS 5546:1990

Installation of hot water supplies for domestic

 

purposes

BS 5440-1:1990

Flues

BS 5440-2:1989

Air supply

BS 5449:1990

Forced circulation hot water systems

BS 6789:1987

Installation of gas fired hot water boilers of rated

 

input not exceeding 60kW

BS 6891:1989

Installation of low pressure gas pipe up to 28mm

BS 7671:1992

IEE wiring regulations

BS 4814:1990

Specification for expansion vessels

BS 5482:1994

Installation of LPG

The appliance may be installed in any room or indoor area, although particular attention is drawn to the requirements of the current I.E.E. Wiring Regulations, and in Scotland, the electrical provisions of the Building Regulations applicable in Scotland, with respect to the installation of the appliance in a room containing a bath or shower.

Where a room-sealed appliance is installed in a room containing a bath or shower the appliance and any electrical switch or appliance control, utilising mains electricity should be situated so that it cannot be touched by a person using the bath or shower.

The location must permit adequate space for servicing and air circulation around the appliance as indicated in paragraph 2.4.

The location must permit the provision of an adequate flue and termination. For unusual locations special procedures may be necessary.

BS 6798-1987 gives detailed guidance on this aspect.

A compartment used to enclose the appliance must be designed specifically for this purpose. No specific ventilation requirements are needed for the installation within a cupboard.

This appliance is not suitable for outdoor installation.

The type C appliances (in which the combustion circuit, air vent intake and combustion chamber are air-tight with respect to the room in which the appliance is installed) can be installed in any type of room.

Secondary ventilation is not required with this boiler. The boiler must be installed on a solid, permanent wall to prevent access from the rear.

5

Page 5
Image 5
Ariston 41-116-07 installation instructions Installation

41-116-07 specifications

The Ariston 41-116-07 is a highly efficient and reliable appliance designed to meet the diverse needs of modern households. This model is primarily recognized for its robust build quality and energy-efficient performance, making it a popular choice among consumers looking for sustainability without sacrificing functionality.

One of the standout features of the Ariston 41-116-07 is its advanced heating technology. The appliance utilizes a high-performance heating element that ensures rapid heating and consistent temperature control. This means that users can enjoy hot water and comfort quickly, with minimal wait times. The innovative design also includes insulation that helps to maintain heat, reducing energy consumption and lowering utility bills.

User convenience is another hallmark of the Ariston 41-116-07. The appliance comes equipped with an intuitive control panel that allows for easy operation. The simple interface helps users to set their desired temperature and monitor performance effortlessly. Additionally, the model includes programmable settings, enabling users to schedule heating cycles according to their lifestyles, further enhancing energy savings.

Safety features are paramount in the design of the Ariston 41-116-07. The appliance includes a range of safety mechanisms such as automatic shut-off, preventing overheating and potential hazards. The built-in sensors continuously monitor the system's operation, ensuring optimal performance while safeguarding the user's home and family.

In terms of installation, the Ariston 41-116-07 excels with its compact size and flexible mounting options. It can be conveniently installed in various locations, whether in a utility room, kitchen, or bathroom, without requiring extensive modifications. This flexibility is ideal for homes with limited space or unique layouts.

Maintenance is also simplified with the Ariston 41-116-07. The appliance is designed with easy-access components, making routine maintenance or troubleshooting straightforward for the average user. This ease of care further contributes to its reputation for reliability, ensuring that the unit operates efficiently over its lifespan.

In summary, the Ariston 41-116-07 stands out for its energy efficiency, user-friendly features, safety mechanisms, versatile installation options, and low maintenance requirements. These characteristics make it a valuable addition to any modern home, catering to the needs of consumers seeking both performance and convenience in their appliances. Whether for daily use or occasional needs, the Ariston 41-116-07 guarantees satisfaction through its innovative technologies and thoughtful design.