Ariston FH 527 AUS, FH 527 IX AUS manual Electrical connections

Models: FH 527 AUS FH 527 IX AUS

1 12
Download 12 pages 36.95 Kb
Page 3
Image 3
Electrical connections

removable without the aid of a tool.

Electrical connections

!Ovens equipped with a three-pole power supply cable are designed to operate with alternating current at the voltage and frequency indicated on the data plate located on the appliance (see below).

Fitting the power supply cable

1. Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram).

2. Loosen the cable clamp screw and remove it, using a screwdriver as a lever (see figure).

3. Remove the wire contact screws L-N- Manual background , then fasten the wires

under the screw heads, respecting the colour code: Blue (N), Brown

(L) and Yellow-Green Verde (Manual background).

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load indicated on the data plate (see side).

The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains, suitable for the load indicated and complying with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). The supply cable must not come into contact with surfaces with temperatures higher than 50°C.

!The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulations.

Before connecting to the power supply, make sure that:

The appliance is earthed and the plug is compliant with the law.

• The socket can withstand the maximum power of

the appliance, which is indicated on the data

AUS

 

plate (see below).

 

The voltage must be in the range between the values indicated on the data plate (see below).

The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do

not use extension cords or multiple sockets.

!Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

!The cable must not be bent or compressed.

!The cable must be checked regularly and replaced by authorised technicians only (see Assistance).

!The manufacturer declines any liability should these safety measures not be observed.

Manual background DATA PLATE

 

width cm 43.5

Dimensions

height cm 32

 

depth cm 41,5

 

 

Volume

lt. 58

 

 

Electrical

voltage: 220-240V ~ 50/60Hz o 50Hz

(see data plate) maximum power

connections

absorbed 2250W

 

 

 

 

Directive 2002/40/EC on the label of

 

electric ovens Norm EN 50304

 

Energy consumption for Natural

ENERGY LABEL

convection heating mode:

 

= Convection

 

Declared energy consumption for

 

Forced convection Class

 

heating mode: > Fan assisted

This appliance conforms to the following European Economic Community directives:

-2006/95/EEC of 12/12/06 (Low Voltage) and subsequent amendments;

-2004/108/EEC of 15/12/04 (Electromagnetic Compatibility) and

subsequent amendments; - 93/68/EEC of 22/07/93 and subsequent amendments.

- 2002/96/EC and subsequent amendments.

3

Page 3
Image 3
Ariston FH 527 AUS, FH 527 IX AUS manual Electrical connections