Ariston FC 97 P Electrical connection, Installation, Connection, Inner dimensions of the oven

Models: FD 96 P FC 97 P FD 97 P FB 86 P FO 97 P

1 14
Download 14 pages 30.39 Kb
Page 13
Image 13
Electrical connection

Installation

Built-in installation of FC 97 P (see figure on the right)

1.Place brackets "A" well against the oven support blocks "B".

2.Place the tabs "C" well against brackets "A". In particular, if the cabinet side panel:

is 16 mm thick: mount the tab so that the number 16 it features is facing you;

is 18 mm thick: mount the tab so that the part without any wording is facing you;

is 20 mm thick: do not mount the tab.

3.Fasten the brackets and tabs on the oven cabinet side panel using screws "D".

4.Fasten the oven to the cabinet using the screws and plastic washers "E".

16

16

D C

16

16

B

C

D

AConnection

C

D

E

E

Electrical connection

Connection

First check the mains electricity supply available (number of phases - voltage - maximum power necessary) to ensure these are compatible with the requirements of the Ariston appliance to be connected.

Ariston ovens can adapt to the following electrical systems:

Using the appliance without correct earthing is highly dangerous.

Important: After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

Electrical connections

Voltage

Fuse

Frequency

Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FR-AT-BE-DE-GP-ES-IE-IL-IS-IT-DK

 

 

 

 

 

LU-RE-FI-GB-GR-PT-SE-MA-NZ-NL

 

 

 

 

 

230 V-1+N ~ 50 Hz

16 A

N

 

L

CY-MT-AU-NZ-KW

1,5 mm²

 

 

 

 

 

 

 

 

 

240 V-1+N ~ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

FR-BE-NO

16 A

 

 

 

 

 

 

 

 

 

230 V-2 ~ 50 Hz

1,5 mm²

L2

L1

 

 

 

 

 

 

 

You can connect your furnace to the electric installation by means of a case of connection. You defer to the table for the minimal wire sections and the calibration of the protection measures according to the branch.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3 mm - should be installed between the appliance and the mains.

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force in the country where the appliance is fitted).

The plug must be accessible at all times.

Unplug the appliance before all operations, even when replacing the oven lamp.

This appliance conforms with the following European Community directives:

DBT 73/23 EEC modified by 93/68/EEC directive

CEM 89/336/EEC modified by 92/31/EEC and 93/68/EEC directives

Inner dimensions of the oven:

 

width

43.5 cm

depth

40.0 cm

height

32.0 cm

Inner volume of the oven:

54 litres

Voltage and frequency of power supply:

230V~50Hz : 2800 W

240V~50Hz : 3050 W

37