27
Fig. 31
LEGEND
1NTC Connectors
2Display Connectors
3EEPROM Button
424V DC Supply
5Fan Connector
6Flame Detection Connector
7Fuses 2A 230V (X2)
8230V Connector
9Auxillary 230V Connector
10 Actuators 230V Connector
11 Time Clock Connector (Internal)
12 Room Thermostat Connector
13 Remote Control Connector
14 Under Floor Heating Connector
15 Not Used
1
5
1112
13
14
15
2
3
4
8
97
6
10
- If a remote time clock is to be fitted, using a volt-free switching time clock, remove the link wire and connect the
switching wires from the time clock following points above (see also DiagramB Fig. 32).
- If using an external time clock and room thermostat, remove the link wire and connect in series as above (see also
Diagram C Fig. 32).
Live and Neutral connections to operate the clock motor must be taken from a suitable source.
Connector 11 (Fig. 31), is provided for connecting an optional integral time clock or programmer, for fitting instructions, please
refer to those provided with the clock or page 8 of this manual.
Fig. 32
CONNECTOR 12 CONNECTOR 12
CONNECTOR 12