39
Menu - 2 - Boiler conditionsIndicates the conditions or the configurations of the boiler5 ” Menu - 1 - Default register
Record the last 10 defaultsx times
once
DISPLAY
ACTION CONFIGURATION
Note --is displayed if no default is recorded
Section Digit 1 Digit 2 Digit 3 and 4
Last default occured 1 0 code from 01 to 99
Last but one default occurred 1 1 code from 01to 99
... 1... code from 01to 99
Last default occurred before the previous
one 1 9 code from 01to 99
x times
Section Digit 1 Digit 2 Digit 3 and 4
Software version of display PCB 2 0 code from 01to 99
Software version of main PCB 2 1 code from 01to 99
Flue type 2 2 4: Condensation
Fan speed (in hundreds of rpm) 2 3 from 01to 99
Theoretical position of the 3 way valve
System plus only 2 4 0: DHW
1: CH
DHW flow temperature in °C 2 5 from 01to 99
CH flow temperature in °C 2 7 from 01 to 99
CH return temperature in °C 2 8 from 01 to 99
Outside temperature in °C2 9 from 01 to 99