ArtDio IPS-2000 user manual FXO & FXS port System Auth

Models: IPS-2000

1 88
Download 88 pages 51.46 Kb
Page 39
Image 39

 

IPS-2000 Series User’s Manual/使用手冊

 

 

Field Name

Description

 

 

ICMP Not Echo

Default No, responding to the message of ping, if select “Yes" not

 

responding to the message of ping.

Send Anonymous CID

Default No, Have no Call out security function, send information of the

 

Gateway, if Select “Yes"do not send information of the Gateway

 

 

Bill signal

Default Disable. Turn on polarity reversal functions to notice Billing system.

 

(Polarity Reversal, Tone_12K, Tone_16K). Support FXS Port

 

 

CPC Delay

Default 2.When received the hang-up signal, how many seconds need to wait

 

to drop the Voltage to Zero. Support FXS Port.

 

 

CPC Duration

Default time is 0ms.(No voltage dropped) When voltage dropped to Zero, how

 

many ms need to continue. Support FXS Port.

 

 

Send Flash event

Default Disable , User could Select DTMF Event or SIP Info to Send flash

 

event.

 

 

SIP Encrypt

Default Disable , IPS-2000 Plus have INFINET, AVS, WALKERSUN1.

 

WALKERSUN2 four format for SIP encryption.

 

This service is provided by use environment.

 

 

PPPoE retry period

Default is 5 Seconds. Set interval is [5~255]. When PPPoE dial failure, how

 

many seconds need to wait before redial.

 

 

System Log Server

Provide system information which to store Log server address at the System.

 

 

System Log Type

Default None (Disable).System Log information type. Provided None, Call

 

Statistics, General Debug, Call Statistics + General Debug, SIP Debug, Call

 

Statistics + SIP Debug, General Debug + SIP Debug, All.

 

 

3.6.6 FXO & FXS port

3.6.7 System Auth

To configure the user logins of the IPS-2000 Series.

39

Page 39
Image 39
ArtDio IPS-2000 user manual FXO & FXS port System Auth